The Tool Desk
Outbyte PC Repair FREEClear out junk files and repair common Windows errorsFree Scan →Outbyte Driver Updater FREEScan for outdated or missing drivers - takes under a minuteDriver Scan →Some links on this page are affiliate links: if you buy through them we may earn a commission, at no extra cost to you.
A native .NET 8 or .NET 10 integration with Rockwell Automation’s Fiix CMMS is entirely practical, but it is not a normal REST client. Fiix has official SDKs only for Java and JavaScript; C# applications must implement Fiix’s POST-based JSON protocol themselves or use the independent FiixCmms.Client package. The important constraints are an Enterprise-plan requirement, HMAC-SHA256 authentication, text/plain requests, HTTP 200 responses that can still contain errors, a five-request concurrency limit, and 1,000 calls per day per user license.
This guide shows the protocol first, then two native .NET paths: a hand-written HttpClient implementation with no third-party runtime dependency, and the community NuGet client. It also covers key creation, batching, quotas, sandbox work, licensing, URL mistakes, and the failure modes that make a Fiix integration feel harder than it should.
As an Amazon Associate I earn from qualifying purchases.
What must a .NET Fiix integration actually do?
A Fiix client sends authenticated JSON instructions to one tenant endpoint. The request is always an HTTP POST with UTF-8 content and Content-Type: text/plain; the JSON body selects a CRUD operation such as Find or an RPC method such as Ping. This is the contract in Fiix’s no-SDK guide, not a conventional resource-oriented REST API.
The production endpoint is normally https://<your-subdomain>.macmms.com/api/.... A sandbox address may look like https://yourinstance.fiixsandbox.com/api/. Use the exact environment URL Fiix gives your account. The live path is /api/; do not copy examples that use /api/v2/.
Popular on Amazon
- 【90 Degree Full Function USB C Adapter】Supports the latest USB4 standard for up to 40Gbps of bandwidth, 8K video support, and up to 240W Fast charging; Support USB PD 3.1 Extended Power Range (EPR) including 140W, 180W and 240W. Your productivity is easily doubled. *Warm Tip: For the best fit, please make sure the USB-C port is fully exposed; thick or bulky cases may affect compatibility.
- 【Reliable Quality】Made from high-quality, scratch-resistant aluminum alloy, delicate metal frame. get excellent wear resistance and heat dissipation. Non-Slip Design for easier insertion and removal.
- 【Small and portable】Ultra thin size, ultra compact design, a petite physique that matches the minimalist design of your modern laptops. Coming with a slim figure that won't block the port next to the one it's plugged into.
- 【Compatibility】Widely work with most usb c, thunderbolt 4/3 devices. Compatibilit for ROG Ally, Steam Deck, Switch, MacBook Pro, Quest 3 VR headset, Surface Book 2, iPhone 18/17/16/15, Samsung Galaxy S23/S22/S21, Note 20/10, Google Pixel, ChromeBook, etc.
- 【Excellence Customer Support】If you experience any issues or cable failure, simply reach out to our dedicated customer service team. We provide a prompt response within 18 hours, providing you with the necessary technical support to resolve any concerns.
Every authenticated URL carries these query parameters:
service=cmmstimestamp: Unix epoch time in millisecondsappKey: the application key, normally beginningmacmmsackpaccessKey: the access key, normally beginningmacmmsaakpsignatureMethod=HmacSHA256signatureVersion=1
The Authorization header is the lowercase hexadecimal HMAC-SHA256 digest of the complete URL you are sending, with only http:// or https:// removed. The secret key is the HMAC key. It is not OAuth, and it is not a bearer token.
Request bodies include _maCn (for example, FindRequest, AddRequest, ChangeRequest, RemoveRequest, or RPCRequest). They may also include a numeric requestId, requestSentUnixTime, and a clientVersion object containing major, minor, and patch.
Responses are JSON delivered as text/plain;charset=utf-8. A successful result generally has object or objects; failures are represented by an error object with fields such as leg, code, message, and stackTrace. Fiix can return that error with HTTP status 200, so an HTTP-success check alone is wrong.
Does Fiix have a .NET SDK?
No official .NET SDK exists. Fiix states in its API FAQ that its official SDKs are Java and JavaScript; all other languages consume the API directly through the no-SDK documentation. A Microsoft-stack team therefore chooses between owning a small C# protocol layer and adopting an independent community client.
Rockwell’s FactoryTalk Optix Fiix Library is a separate OT/HMI integration for Optix runtimes. It uses the same Fiix Client API and keys for scenarios such as meter readings, offline tracking, and work-order faceplates, but it is not a general-purpose .NET SDK for an ASP.NET service, Windows worker, or MES connector.
Free tools Windows power users keep installed
One-click scans. No signup required.
What do I need before writing code?
- An Enterprise subscription. Fiix says API access is available to Enterprise-plan customers. Confirm entitlement with your Fiix representative before debugging code.
- A dedicated API user. API keys inherit the owning user’s permissions. Create a least-privilege integration identity rather than attaching keys to a human administrator.
- An API application. As an administrator, open Settings > Connect Management > MA Connect API Application Settings (the FAQ also labels this Fiix API Application Settings) and choose New API Application.
- Three credentials and an environment URL. Fiix provides an Application Key, Access Key, and Secret Key. The secret is displayed once; store it immediately in a secret manager.
- A sandbox or mock. Enterprise subscribers can request a fully functional sandbox from their Fiix representative. For local CI, the community project includes a mock API that listens on
http://localhost:5100, validates HMAC, and seeds in-memory CRUD data.
Keys are account-specific: the API sees exactly what the owning user is allowed to see. If a query appears to “miss” data, check the integration user’s site, role, and object permissions before changing code.
Also popular on Amazon
- 5-in-1 Connectivity: Equipped with a 4K HDMI port, a 5 Gbps USB-C data port, two 5 Gbps USB-A ports, and a USB C 100W PD-IN port. Note: The USB C 100W PD-IN port supports only charging and does not support data transfer devices such as headphones or speakers.
- Powerful Pass-Through Charging: Supports up to 85W pass-through charging so you can power up your laptop while you use the hub. Note: Pass-through charging requires a charger (not included). Note: To achieve full power for iPad, we recommend using a 45W wall charger.
- Transfer Files in Seconds: Move files to and from your laptop at speeds of up to 5 Gbps via the USB-C and USB-A data ports. Note: The USB C 5Gbps Data port does not support video output.
- HD Display: Connect to the HDMI port to stream or mirror content to an external monitor in resolutions of up to 4K@30Hz. Note: The USB-C ports do not support video output.
- What You Get: Anker 332 USB-C Hub (5-in-1), welcome guide, our worry-free 18-month warranty, and friendly customer service.
How do I sign a Fiix request with HMAC-SHA256 in .NET?
Sign the exact URL that goes over the wire, after all query parameters have been added. Remove only the URI scheme, encode that remaining text as UTF-8, compute HMAC-SHA256 with the UTF-8 secret, and emit lowercase hexadecimal. A mismatch in query ordering, encoding, timestamp, host, or trailing slash changes the digest.
using System.Security.Cryptography;
using System.Text;
static string CreateFiixSignature(Uri requestUri, string secret)
{
// Fiix signs the URL without http:// or https://.
var value = requestUri.AbsoluteUri;
if (value.StartsWith("https://", StringComparison.OrdinalIgnoreCase))
value = value[8..];
else if (value.StartsWith("http://", StringComparison.OrdinalIgnoreCase))
value = value[7..];
var keyBytes = Encoding.UTF8.GetBytes(secret);
var valueBytes = Encoding.UTF8.GetBytes(value);
using var hmac = new HMACSHA256(keyBytes);
var digest = hmac.ComputeHash(valueBytes);
return Convert.ToHexString(digest).ToLowerInvariant();
}
The C# sketch in Fiix’s no-SDK documentation is useful, but its illustrative getRequestUri() omits some production query fields. Build the complete URI first, then sign that URI rather than reconstructing a shorter string inside the signer.
A minimal request helper
using System.Net.Http.Headers;
using System.Text;
using System.Text.Json;
static async Task<JsonDocument> SendFiixAsync(
HttpClient http,
string baseUri,
string appKey,
string accessKey,
string secret,
object payload,
CancellationToken cancellationToken)
{
var builder = new UriBuilder(baseUri);
var query = new Dictionary<string, string>
{
["service"] = "cmms",
["timestamp"] = DateTimeOffset.UtcNow.ToUnixTimeMilliseconds().ToString(),
["appKey"] = appKey,
["accessKey"] = accessKey,
["signatureMethod"] = "HmacSHA256",
["signatureVersion"] = "1"
};
builder.Query = string.Join("&", query.Select(kvp =>
$"{Uri.EscapeDataString(kvp.Key)}={Uri.EscapeDataString(kvp.Value)}"));
var uri = builder.Uri;
using var request = new HttpRequestMessage(HttpMethod.Post, uri);
request.Headers.Authorization = new AuthenticationHeaderValue(
"", CreateFiixSignature(uri, secret));
var json = JsonSerializer.Serialize(payload);
request.Content = new StringContent(json, Encoding.UTF8, "text/plain");
using var response = await http.SendAsync(request, cancellationToken);
response.EnsureSuccessStatusCode(); // HTTP 200 still requires an error-object check.
await using var stream = await response.Content.ReadAsStreamAsync(cancellationToken);
return await JsonDocument.ParseAsync(stream, cancellationToken: cancellationToken);
}
Some .NET versions reject an empty authentication scheme when assigning AuthenticationHeaderValue. In that case, set the raw header with request.Headers.TryAddWithoutValidation("Authorization", signature); the Fiix contract requires the digest value, not a Bearer prefix. Verify the exact header format against the no-SDK examples for your tenant.
Do these 3 things before closing this tab:
1Clear out junk files and repair common Windows errors2Fix the driver behind crashes, sound loss and screen glitches3Repair Windows errors before they cause bigger problemsDo not create a new HttpClient for each work order. Register one through IHttpClientFactory (or reuse a long-lived instance), set sensible timeouts, and pass cancellation tokens through every call.
How do I form CRUD and RPC payloads?
The body, not the URL path, chooses the operation. Fiix uses Hungarian-style field names such as intSiteID, strName, dttDateCreated, bolIsActive, dblHourlyRate, and qtyOnHand. Display-value fields commonly use a dv_ prefix, for example a dv_intCategoryID field.
Find example
var findAssets = new
{
_maCn = "FindRequest",
className = "Asset",
fields = new[] { "id", "strName", "intSiteID", "dv_intSiteID" },
filters = new[]
{
new { ql = "intAssetLocationID = ?", parameters = new object[] { 42 } }
},
orderBy = new[] { "strName" },
startIndex = 0,
maxObjects = 100
};
The exact filter shape depends on the object and operation documented in the Fiix API reference. The query language uses ? placeholders. The community client documents operators including =, !=, comparison operators, LIKE, AND, OR, IS NULL, and IS NOT NULL.
Add, change, remove, and RPC
An add request supplies an object and fields; a change supplies an object identifier, change fields, and requested return fields; remove supplies an identifier. An RPC request supplies name, action, and parameters. Documented RPC examples include Ping, GetAccessibleSites, GetTimezone, Calendar, DashboardWidget, CustomFields, and FollowOnWorkOrders. Treat the API reference as authoritative for each method’s parameter names and types.
Also popular on Amazon
- Sleek 7-in-1 USB-C Hub: Features an HDMI port, two USB-A 3.0 ports, and a USB-C data port, each providing 5Gbps transfer speeds. It also includes a USB-C PD input port for charging up to 100W and dual SD and TF card slots, all in a compact design.
- Flawless 4K@60Hz Video with HDMI: Delivers exceptional clarity and smoothness with its 4K@60Hz HDMI port, making it ideal for high-definition presentations and entertainment. (Note: Only the HDMI port supports video projection; the USB-C port is for data transfer only.)
- Double Up on Efficiency: The two USB-A 3.0 ports and a USB-C port support a fast 5Gbps data rate, significantly boosting your transfer speeds and improving productivity.
- Fast and Reliable 85W Charging: Offers high-capacity, speedy charging for laptops up to 85W, so you spend less time tethered to an outlet and more time being productive.
- What You Get: Anker USB-C Hub (7-in-1), welcome guide, 18-month warranty, and our friendly customer service.
Unknown response properties should be ignored. Fiix describes API changes as additive, so tolerant JSON deserialization is safer than failing whenever a new field appears.
Which native .NET path should I choose?
Choose the hand-written client when you need only a few operations or cannot accept a copyleft dependency. Choose FiixCmms.Client when its DTO coverage, batching, retry behavior, and mock API justify adopting an independent package after legal review.
| Decision point | Path A: your HttpClient layer | Path B: FiixCmms.Client |
|---|---|---|
| Support status | Based directly on Fiix’s documented no-SDK contract | Independent community project; not a Rockwell product |
| Target frameworks | Your choice, including .NET 8 and .NET 10 | 1.0.1-rc4 targets net8.0 and net10.0 |
| Modeling | You map JSON and Hungarian field names | 107 DTO classes, generic Prepare* helpers, and ExtraFields |
| Operations | You implement CRUD, RPC, and batch payloads | CRUD plus 18 documented RPC methods, batch support, async-only APIs |
| Reliability features | You own 429 handling, cancellation, and pooling | Built-in HMAC, cancellation, 429 retry, and IHttpClientFactory registration |
| Offline development | Build your own fake or contract test | CLI and FiixCmms.MockApi are included in the repository |
| License | Protocol documentation is Apache 2.0 | License metadata and repository file say GPL-3.0; README also contains Apache-2.0 and commercial-license language |
How do I use FiixCmms.Client in ASP.NET Core?
The current package is FiixCmms.Client 1.0.1-rc4, updated 5 August 2026. Its author reports verification against API version 2.48.1. Install the prerelease explicitly:
dotnet add package FiixCmms.Client --version 1.0.1-rc4
Register the client with the package’s current options. Use BaseUri and an /api/ endpoint, not the BaseUrl//api/v2/ combination shown in some older articles.
Recommended Free Tools
builder.Services.AddFiixClient(options =>
{
options.AppKey = builder.Configuration["Fiix:AppKey"]!;
options.AccessKey = builder.Configuration["Fiix:AccessKey"]!;
options.SecretKey = builder.Configuration["Fiix:SecretKey"]!;
options.BaseUri = builder.Configuration["Fiix:BaseUri"]!;
});
Inject FiixCmmsClient and prepare an operation from its generic DTO type:
public sealed class AssetService(FiixCmmsClient fiix)
{
public async Task<object?> GetAssetAsync(
int id, CancellationToken cancellationToken)
{
var request = fiix.PrepareFindById<Asset>(id);
var response = await fiix.FindByIdAsync(request, cancellationToken);
if (response.Error is not null)
throw new InvalidOperationException(
$"Fiix error {response.Error.Code}: {response.Error.Message}");
return response.Object;
}
}
Other helpers include PrepareFind<T>(), PrepareAdd<T>(), PrepareChange<T>(), PrepareRemove<T>(), PrepareRpc(), and PrepareBatch(). The generic preparation step supplies the class name. The client is async-only; use await all the way through your service and controller rather than blocking on .Result.
Always branch on response.Error before reading Object or Objects. Cancellation is represented in the response with error legs such as CLIENT_REQUEST_CANCELLED or CLIENT_REQUEST_SEND_OR_RECEIVE, so callers should preserve that distinction in logs and retry policy.
Also popular on Amazon
- Portable and powerful USB-C HUB: BENFEI USB Type-C HUB, with super-soft and knot-free silicone woven design cable, meets most mobile office needs. Compact, lightweight, stylish, and powerful portable USB C Hub equipped with 1 x HDMI port, 1 x 100W charging, and 3 x USB ports. 18-month warranty, 24-hour response, to ensure you feel at ease when using our product.
- Design centered on comfort and reliability: Thanks to BENFEI's end-to-end in-house cable production capability, in-house PCBA and assembly capability, using the industry's most advanced silicone woven design and process, 20cm cable in length, no knots, super-soft, the HUB is easy to use in all scenarios: laptop, tablet, stand etc. Super-soft, 25000+ life cycles, to meet your daily carrying and office needs.
- 100W Charging: Support up to 90W USB C pass-through charging via Type-C port to keep your laptop powered. 10W is reserved for other interface operations. No data and video function on the Type-C port.
- 4K HDMI Display: The HDMI port supports media display at resolutions up to 4K 30Hz, keeping every incredible moment detailed and ultra vivid. Please note that the C port of the Host device needs to support video output.
- Transfer Files in Seconds: Transfer files and from your laptop at speeds up to 10 Gbps with USB A 3.2 port. Extra 2 USB A 2.0 ports are perfectly for your keyboards and mouse.
What is the FiixCmms.Client license risk?
Review the package before placing it in a proprietary MES, ERP, or factory-floor product. The NuGet metadata and GitHub license file identify GPL-3.0 or GPL-3.0-or-later. The README simultaneously says the project is dual-licensed under GPLv3, asks proprietary users to acquire a commercial license, and contains a later Apache License 2.0 statement. Those statements conflict.
Do not decide that the dependency is permissive based on one README paragraph. Ask the author for a written license grant, have counsel reconcile the repository’s license files and README, and pin the reviewed commit/package. If your organization cannot accept GPLv3 uncertainty, implement Path A or isolate the client behind a separately reviewed service.
How do I stay under Fiix’s API quota?
Fiix documents a limit of 1,000 API calls per day per user license and five concurrent API calls per tenant. An account with 10 purchased user licenses therefore has a documented allowance of 10,000 calls per day. The quota is not a suggestion: design around it from the first integration test.
Batch requests whenever operations are independent. One HTTP batch containing multiple operations counts as one API call against the daily cap; responses are returned in request order. The community client author recommends batches of 10–50 operations, which is guidance rather than a Fiix SLA. Keep batches small enough to retry safely and to avoid oversized payloads.
- Request only fields you need; do not retrieve full objects to display one name.
- Use
dv_display fields where available instead of an additionalFindByIdfor every related object. - Throttle workers to five or fewer concurrent calls and leave headroom for operational jobs.
- Use the community client’s 429 retry behavior, or implement bounded exponential backoff yourself. Its default maximum wait for throttling is 5,000 ms.
- Run CI against the local mock or recorded contract fixtures, not the sandbox, so tests do not consume the daily allowance.
HTTP 429 is the throttle signal. A retry queue should distinguish 429 from authentication, permission, validation, and permanent object errors; retrying every error simply burns the remaining quota.
How should I create and protect API keys?
Create the API application under an administrator account, but bind it to a dedicated least-privilege API user. Store the secret in Azure Key Vault, another managed secret store, or an equivalent protected configuration system; never commit it to a repository, container image, or client-side application.
Fiix shows the secret only once. If it is lost, create a new API application and rotate the integration rather than expecting the old value to be recoverable. During rotation, support both credentials briefly if your deployment process requires a zero-downtime cutover, then revoke the old application after all workers have switched.
Also popular on Amazon
- 【Read before You Buy】 Note: This adapter is USB 2.0 version and cannot transmit HDM, VGA, or other video signals. Nevertheless, they are fully capable of charging devices,duplicating files, and can be seamlessly integrated with USB-C earphones, wireless network adapters, and SD card adapters.
- 【Easy to Use and Safe】Thanks to modern manufacturing techniques, we've made these adapters sufficiently compact so that they can remain inserted in your device without noticeable protrusion or inconvenience. This means you don't have to constantly plug and unplug them, reducing the likelihood of wear and misalignment, and making them more convenient to carry around.
- 【Reliable Quality】Engineered for enhanced durability, durable aluminum alloy shell material,get excellent wear resistance and heat dissipation,the male USB C and female USB connectors & the male USB and female USB C connectors are designed to be plugged and unplugged up to 20000 times. Provides data transfer, device charging, memory space expansion, and additional computer peripherals.
- 【Think more for you】Do you need to connect a USB-C-enabled device to an odd device that only has USB-A ports? Then these USB-A male to USB-C female adapters are made for you.Simply insert the adapter into the USB-A port on the device, and you can instantly connect your USB-C device to the device that originally didn't have the correct connection port.
- 【Trusted xiwxi Quality and Service】As a responsible brand seller, you will receive xiwxi's 12-month Quality assurance and lifetime friendly customer service, you're not just buying a product,you're investing in peace of mind with all-round quality and exceptional customer service.
Log the tenant and operation type, not the secret, full Authorization header, or complete signed URL. Signed URLs include credentials in query parameters, so redact them before sending diagnostic data to a log or tracing system.
What are the most common integration failures?
- HMAC mismatch
- Sign the exact final URL, including every query parameter, with the scheme removed. Use UTF-8 for both URL text and secret, lowercase hexadecimal output, and ensure the timestamp and trailing slash are identical between signing and sending.
- HTTP 200 treated as success
- Parse JSON and inspect
erroron every response. Captureleg,code, andmessage; usestackTraceonly in protected diagnostics. - REST assumptions
- There is no separate URL such as
/assets/123. Post to the API endpoint and selectFindRequest,AddRequest, or an RPC in the body. - Wrong base path
- Use the tenant host and
/api/path Fiix supplied. Do not substitute/api/v2/because an old blog example uses it. - Socket exhaustion
- Reuse an
HttpClientor useIHttpClientFactory; never construct one for each work order. - Deadlocks
- The community client is asynchronous. Propagate
await; blocking on.Resultcan deadlock ASP.NET request contexts. - Permission or object-version errors
- API keys inherit user permissions, and Fiix’s object versions differ. The v5 User object supports full CRUD while v6 User is read-only through the API; v6 Work Orders and Equipment tables are not reachable as v5 objects.
- Secret loss or administrator blast radius
- Rotate by creating a new application and use a dedicated integration identity with only required sites and roles.
- Sandbox unavailable
- Request the Enterprise sandbox through a Fiix representative, or use the community MockApi for local development and CI.
- License uncertainty
- Treat the community package as GPL-3.0-or-later until the author and license files provide a written resolution. Choose the no-SDK implementation if legal review cannot approve it.
How should a production integration be structured?
- Configuration boundary: load App Key, Access Key, Secret Key, and Base URI from a secret/configuration provider. Validate that the base URI is an allowed Fiix tenant or sandbox host.
- Transport boundary: use a pooled
HttpClient, a single signing component, explicit UTF-8text/plaincontent, and cancellation tokens. - Protocol boundary: model request envelopes and response envelopes separately from business DTOs. Preserve unknown JSON properties where practical.
- Error boundary: convert Fiix’s
errorobject into typed application errors. Keep HTTP status, Fiix code, leg, and correlation information together. - Quota boundary: queue and batch operations, cap concurrency below five, and expose daily-call consumption as an operational metric.
- Domain boundary: avoid leaking Hungarian API field names into every business class. Map them at the adapter edge, while retaining the original names for troubleshooting.
- Deployment boundary: rotate keys, roll out one worker first, verify Ping and a read-only Find, then enable writes such as work-order creation.
For write operations, make your own idempotency strategy because a network timeout does not tell you whether Fiix committed the request. A retry of an Add can create a duplicate work order unless you first search for a durable external reference or design a reconciliation job.
What’s actually slowing this PC down?
Pick the symptom - the matching free tool is one click away.
When should I use another Rockwell integration path?
Use the FactoryTalk Optix Fiix Library when the caller is an Optix HMI or runtime and you want its supplied faceplates and connector components. It is documented in Rockwell’s Release 1.01 reference manual and is not a replacement for a general ASP.NET integration.
Asset Intelligence’s CMMS Integration Setup asks for the same Application Key, Access Key, API Secret, and environment URL, then provides a connection test and work-order synchronization. If the organization standardizes on Boomi, Fiix’s Integration Hub material describes an iPaaS route; that is a vendor integration process rather than a .NET library.
Teams that can move outside .NET can use Fiix’s Java client and examples, including the official Java examples. That does not change the Enterprise entitlement, key handling, quota, or HTTP contract.
What should I verify before go-live?
- Enterprise API access is active for the target tenant.
- The API user is dedicated, least-privilege, and has access to every required site and object.
- The secret is stored outside source control and a rotation procedure is documented.
- The signer uses the exact sent URL, stripped scheme, UTF-8 bytes, HMAC-SHA256, and lowercase hex.
- Every request is POST with UTF-8
text/plainand a valid_maCnbody. - Every response checks
error, even when HTTP status is 200. - Batching, five-call concurrency limits, 429 backoff, and daily quota metrics are implemented.
- Tests run against a mock or sandbox without exhausting production quota.
- Any use of
FiixCmms.Clienthas written license approval, especially for closed-source MES or ERP software. - Read-only reconciliation and duplicate-prevention behavior are defined for timed-out writes.
The result is a normal .NET service at the application level, but a deliberately non-REST adapter at the Fiix boundary. Once signing, response errors, permissions, and quota are treated as first-class protocol concerns, the integration is predictable rather than mysterious.
Quick wins for a faster PC:
Scan for outdated or missing drivers - takes under a minuteDriver Scan →Clear out junk files and repair common Windows errorsFree Scan →Fix the driver behind crashes, sound loss and screen glitchesFind Drivers →Frequently Asked Questions
Can an Azure Function call the Fiix API directly?
Yes. Use a static or dependency-injected HttpClient, keep the three keys in the function app’s managed secret store, and cap parallel executions so a scale-out event does not exceed Fiix’s five-concurrent-call limit. Queue-triggered batching is usually safer than allowing every event to issue an independent request.
How can I tell whether a Fiix failure is authentication or a permission problem?
Log the Fiix error code, leg, and message together with the tenant and operation name, while redacting signed URLs and credentials. A valid HMAC with an underprivileged API user commonly produces a permission or object-access error; changing the signature will not fix that, so verify the owning user’s role and site scope.
Can I safely retry a timed-out work-order creation?
Not blindly. A timeout can occur after Fiix accepted the write, so retrying an Add may create a duplicate. Use an external reference that you can search before retrying, or run a reconciliation process that compares your source event with Fiix work orders.
Where can I find the current list of Fiix RPC methods?
Use the versioned API reference at fiixlabs.github.io/api-documentation for the tenant’s supported methods and parameters. Community-client method counts are implementation snapshots, not a promise that every future or tenant-specific RPC is included.