WUAgent error 0x8007000E means E_OUTOFMEMORY, but it does not prove that a Configuration Manager (SCCM) client has run out of physical RAM. The reliable way to fix a failed software-update search is to correlate the failure in WUAHandler.log and WindowsUpdate.log, identify the scan source and SUP/WSUS endpoint, then follow the branch supported by the surrounding error text. Microsoft says that WUAHandler reports the result returned by the Windows Update Agent; WindowsUpdate.log normally contains the additional context needed to choose a repair.
There is no evidence-based, universal “0x8007000E fix” such as adding memory, deleting the client cache, or installing one update package. Use the procedure below to separate component or data-store problems, proxy and HTTP failures, SUP reachability issues, and a narrow legacy Windows 7/Server 2008 R2 case.
As an Amazon Associate I earn from qualifying purchases.
What does WUAgent error 0x8007000E mean?
In Microsoft’s HRESULT reference, 0x8007000E maps to E_OUTOFMEMORY. That is an error class, not a diagnosis of the machine’s installed RAM. A Windows Update search can return this code when an operation cannot obtain a required resource, and the HRESULT alone does not identify whether the trigger is memory pressure, a damaged update data store, a client or agent defect, or another condition.
The wording often appears in Configuration Manager as a failed scan or “Failed to search” message. A historical Microsoft Q&A report contains the lines WARNING: WU client failed Searching for update with error 0x8007000e, PopulateDataStore failed, and Sync of Updates. That report came from an individual Windows 7 incident in 2016; it is useful for recognizing log language, not for proving a universal root cause.
Popular on Amazon
- 【90 Degree Full Function USB C Adapter】Supports the latest USB4 standard for up to 40Gbps of bandwidth, 8K video support, and up to 240W Fast charging; Support USB PD 3.1 Extended Power Range (EPR) including 140W, 180W and 240W. Your productivity is easily doubled. *Warm Tip: For the best fit, please make sure the USB-C port is fully exposed; thick or bulky cases may affect compatibility.
- 【Reliable Quality】Made from high-quality, scratch-resistant aluminum alloy, delicate metal frame. get excellent wear resistance and heat dissipation. Non-Slip Design for easier insertion and removal.
- 【Small and portable】Ultra thin size, ultra compact design, a petite physique that matches the minimalist design of your modern laptops. Coming with a slim figure that won't block the port next to the one it's plugged into.
- 【Compatibility】Widely work with most usb c, thunderbolt 4/3 devices. Compatibilit for ROG Ally, Steam Deck, Switch, MacBook Pro, Quest 3 VR headset, Surface Book 2, iPhone 18/17/16/15, Samsung Galaxy S23/S22/S21, Note 20/10, Google Pixel, ChromeBook, etc.
- 【Excellence Customer Support】If you experience any issues or cable failure, simply reach out to our dedicated customer service team. We provide a prompt response within 18 hours, providing you with the necessary technical support to resolve any concerns.
Do not authorize a RAM purchase or a broad client reset from the code alone. First establish what was happening at the exact time of the failure and whether other clients show the same symptom.
Which evidence should I collect before changing the client?
Collect a small, repeatable evidence set before restarting services or renaming update folders. It lets you compare one affected endpoint with a healthy endpoint and prevents a repair from destroying the clues you need.
What’s actually slowing this PC down?
Pick the symptom - the matching free tool is one click away.
- Record the operating-system version and build. Include whether the host is Windows 7, Windows Server 2008 R2, or a newer supported release.
- Record the Configuration Manager client version and site. Note the time zone and the precise time of the failed scan.
- Identify the caller. State whether the scan was initiated by the Configuration Manager Software Updates workload, a scheduled task, Windows Update settings, a maintenance script, or another product. The HRESULT does not identify the caller.
- Determine scope. Is this one device, a collection, a site, or a whole hierarchy? A population-wide failure points you toward shared SUP, policy, certificate, DNS, proxy, or service issues; an isolated failure points toward local state or configuration, although neither pattern is conclusive.
- Preserve the logs around the failure. Save the relevant portion of
WUAHandler.logandWindowsUpdate.logwith timestamps intact. Include several minutes before and after the error so that the initiating request, endpoint selection, and preceding warnings are visible.
Microsoft’s Configuration Manager scan-failure guidance is written around this evidence-first approach. Its original-product-version note references Configuration Manager 2012 and 2012 R2, so validate current guidance against the version of Configuration Manager and Windows you actually operate.
How do WUAHandler.log and WindowsUpdate.log work together?
Read the two logs as a pair, not as competing sources. Microsoft’s wording is explicit: “WUAHandler just reports what the Windows Update Agent reported.” WUAHandler shows the Configuration Manager-side result; WindowsUpdate.log is where the Windows Update Agent generally provides the lower-level context.
- Find the first scan request and its timestamp in
WUAHandler.log. - Use that timestamp to locate the corresponding search in
WindowsUpdate.log. - Capture the lines immediately before
0x8007000E. Look for datastore, synchronization, service, HTTP, proxy, authentication, DNS, or endpoint-selection messages. - Check whether the same error repeats for every scan or only after a particular action, such as policy refresh, software-update evaluation, or a restart.
- Compare the sequence with a healthy client using the same boundary group, policy, and SUP.
A WUAHandler entry that contains only the HRESULT is not enough to select a fix. If WindowsUpdate.log shows a different preceding error, investigate that error first; the final HRESULT may be a downstream result.
Also popular on Amazon
- 5-in-1 Connectivity: Equipped with a 4K HDMI port, a 5 Gbps USB-C data port, two 5 Gbps USB-A ports, and a USB C 100W PD-IN port. Note: The USB C 100W PD-IN port supports only charging and does not support data transfer devices such as headphones or speakers.
- Powerful Pass-Through Charging: Supports up to 85W pass-through charging so you can power up your laptop while you use the hub. Note: Pass-through charging requires a charger (not included). Note: To achieve full power for iPad, we recommend using a 45W wall charger.
- Transfer Files in Seconds: Move files to and from your laptop at speeds of up to 5 Gbps via the USB-C and USB-A data ports. Note: The USB C 5Gbps Data port does not support video output.
- HD Display: Connect to the HDMI port to stream or mirror content to an external monitor in resolutions of up to 4K@30Hz. Note: The USB-C ports do not support video output.
- What You Get: Anker 332 USB-C Hub (5-in-1), welcome guide, our worry-free 18-month warranty, and friendly customer service.
How do I verify the scan source and SUP/WSUS endpoint?
Before repairing anything, prove which update service the client is contacting. A client can have correct network access to one WSUS/SUP while policy points it to another, or it can be using a source different from the one an administrator expects.
Recommended Free Tools
- Review the active Configuration Manager policy and identify the SUP URL and port assigned to the device.
- Confirm that the client resolves the SUP name to the expected address. Check both the short name and fully qualified name if policy uses them.
- Verify that outbound access to the configured WSUS port is allowed from the client network and that any intervening firewall permits the traffic.
- Test the WSUS web-service endpoints named in Microsoft’s guidance:
ClientWebServiceandSimpleAuthWebService. A successful response proves reachability to that endpoint; it does not prove that the update database or agent state is healthy. - Compare the configured endpoint and port with a working client in the same boundary group.
These checks diagnose scan communication in general. They do not establish that network reachability caused 0x8007000E. Only the surrounding log evidence can make that connection.
When should I check WinHTTP proxy settings?
Check proxy configuration when the logs show proxy, HTTP, authentication, or connection failures, or when the affected network requires a proxy. Windows Update Agent uses WinHTTP, and its settings can differ from the WinINET settings used by browsers. A browser opening a WSUS URL therefore does not prove that the agent can use it.
- Display the machine’s WinHTTP proxy configuration with an elevated command prompt:
netsh winhttp show proxy
- Compare the result with the organization’s required proxy path. Check whether a direct connection is expected, whether a proxy requires authentication, and whether the SUP hostname is included in a bypass list.
- Inspect the WindowsUpdate.log lines around the failure for proxy or HTTP status codes. Do not change proxy settings merely because
0x8007000Eappears; Microsoft documents proxy checks for proxy-associated failures, not as a confirmed explanation for this HRESULT. - If a policy change is required, apply it through the organization’s supported configuration method, record the previous value, and repeat the scan while collecting fresh logs.
Keep WinHTTP and browser proxy findings separate in your incident notes. They are different configuration stores and can produce different results.
Should I reset the Windows Update data store?
Resetting the update data store is a conditional repair, not a code-specific cure. Use it only when the logs point to a component or datastore problem and current Microsoft guidance for your Windows and Configuration Manager versions supports the action. The cited Configuration Manager article associates its troubleshooter and SoftwareDistribution reset with particular component-related failures; its listed set does not include 0x8007000E.
Free tools Windows power users keep installed
One-click scans. No signup required.
Also popular on Amazon
- Sleek 7-in-1 USB-C Hub: Features an HDMI port, two USB-A 3.0 ports, and a USB-C data port, each providing 5Gbps transfer speeds. It also includes a USB-C PD input port for charging up to 100W and dual SD and TF card slots, all in a compact design.
- Flawless 4K@60Hz Video with HDMI: Delivers exceptional clarity and smoothness with its 4K@60Hz HDMI port, making it ideal for high-definition presentations and entertainment. (Note: Only the HDMI port supports video projection; the USB-C port is for data transfer only.)
- Double Up on Efficiency: The two USB-A 3.0 ports and a USB-C port support a fast 5Gbps data rate, significantly boosting your transfer speeds and improving productivity.
- Fast and Reliable 85W Charging: Offers high-capacity, speedy charging for laptops up to 85W, so you spend less time tethered to an outlet and more time being productive.
- What You Get: Anker USB-C Hub (7-in-1), welcome guide, 18-month warranty, and our friendly customer service.
A commonly documented reset sequence stops the Windows Update service, renames the data directory, starts the service again, and initiates a new scan. A controlled example is:
net stop wuauserv
ren %windir%SoftwareDistribution SoftwareDistribution.old
net start wuauserv
Afterward, start a scan through the normal Configuration Manager workflow and capture new WUAHandler and WindowsUpdate logs. The exact command and service state may differ on your build, so use the current Microsoft procedure applicable to that operating system.
Plan the change carefully:
- Use an elevated prompt and ensure no maintenance window or deployment depends on the service while it is stopped.
- Keep the renamed directory until the incident is closed, because it can contain useful diagnostic material and may be needed for rollback.
- Expect the client to rebuild update metadata; the next scan can take longer and may generate substantial disk and network activity.
- Do not delete unrelated Configuration Manager client folders or caches as a substitute. The evidence does not show that client-cache deletion fixes this HRESULT.
- If the error returns immediately, stop repeating the reset and return to the logs. Repeated resets can remove context without addressing the underlying condition.
Could low physical memory be the cause?
It is possible for resource pressure to affect a Windows Update operation, but the HRESULT alone does not demonstrate that the host needs more RAM. Check ordinary operating-system evidence—available memory, paging activity, application crashes, and event logs—at the failure time. A memory upgrade is justified only when that broader evidence shows a sustained capacity problem and the platform’s workload requires it.
Do not infer a memory threshold from 0x8007000E; the reviewed Microsoft material publishes no threshold or statistic for this SCCM symptom. If multiple clients with very different hardware fail at the same time, a shared service or policy issue is more plausible than an identical physical-memory shortage, although the logs still decide the branch.
Quick wins for a faster PC:
Fix the driver behind crashes, sound loss and screen glitchesFind Drivers →Repair Windows errors before they cause bigger problemsFix Now →What is the legacy Windows 7 and Server 2008 R2 branch?
A narrow historical case is documented in the 1E 8.1 on-premises known-issues page. It concerns direct internet patch deployment through the “Patch Success” option on Windows 7 or Windows Server 2008 R2 and calls for the relevant Windows Update Client improvement update.
Also popular on Amazon
- Portable and powerful USB-C HUB: BENFEI USB Type-C HUB, with super-soft and knot-free silicone woven design cable, meets most mobile office needs. Compact, lightweight, stylish, and powerful portable USB C Hub equipped with 1 x HDMI port, 1 x 100W charging, and 3 x USB ports. 18-month warranty, 24-hour response, to ensure you feel at ease when using our product.
- Design centered on comfort and reliability: Thanks to BENFEI's end-to-end in-house cable production capability, in-house PCBA and assembly capability, using the industry's most advanced silicone woven design and process, 20cm cable in length, no knots, super-soft, the HUB is easy to use in all scenarios: laptop, tablet, stand etc. Super-soft, 25000+ life cycles, to meet your daily carrying and office needs.
- 100W Charging: Support up to 90W USB C pass-through charging via Type-C port to keep your laptop powered. 10W is reserved for other interface operations. No data and video function on the Type-C port.
- 4K HDMI Display: The HDMI port supports media display at resolutions up to 4K 30Hz, keeping every incredible moment detailed and ultra vivid. Please note that the C port of the Host device needs to support video output.
- Transfer Files in Seconds: Transfer files and from your laptop at speeds up to 10 Gbps with USB A 3.2 port. Extra 2 USB A 2.0 ports are perfectly for your keyboards and mouse.
Treat this as a scenario match, not a general explanation for current Configuration Manager clients:
- Confirm that the operating system is Windows 7 or Server 2008 R2.
- Confirm that the incident involves the documented direct-internet deployment option, rather than a normal SUP scan.
- Verify the exact update and applicability for that legacy platform before installation.
- Do not apply the historical explanation to Windows 10, Windows 11, newer Windows Server releases, or a different deployment path without corroborating log evidence.
The page was last modified on January 26, 2024, but the scenario itself remains legacy and product-specific. Use your organization’s support and patching policy for retired operating systems.
How do I choose the next troubleshooting branch?
Use the strongest evidence in the logs and configuration, not the error label. This decision table keeps the branches separate:
| Evidence you find | Next action | What not to conclude |
|---|---|---|
| Datastore, synchronization, or component corruption messages around the search | Follow the current Microsoft component-repair or data-store-reset procedure for the exact OS and Configuration Manager version; then rescan and compare logs. | That every 0x8007000E failure is fixed by renaming SoftwareDistribution. |
| Proxy, HTTP status, authentication, DNS, or connection errors | Validate WinHTTP settings, name resolution, SUP web services, firewall rules, and configured ports. | That a browser test proves Windows Update Agent connectivity. |
| Correct endpoint policy but failures across a collection or site | Compare SUP health, policy, certificates, boundary-group assignment, and network changes with a healthy client; escalate with synchronized logs. | That the client’s RAM is the common cause. |
| Windows 7/Server 2008 R2 plus the documented direct-internet Patch Success scenario | Investigate the legacy Windows Update Client improvement update and the exact 1E scenario. | That the legacy fix applies to supported modern Windows versions. |
| No corroborating context beyond the HRESULT | Collect a complete log window, system/build information, and event logs; reproduce once under observation if change control permits. | That a code-only prescription is reliable. |
What should I do if the scan still fails after repair?
Stop making repeated changes and prepare an escalation package. Include:
- Operating-system edition, build, architecture, and patch level.
- Configuration Manager site and client version, boundary group, and assigned SUP.
- The scan initiator and exact UTC or local timestamps.
- Relevant excerpts from
WUAHandler.logandWindowsUpdate.log, preserving the lines before the first failure. - Results of SUP name resolution, web-service access, port checks, and
netsh winhttp show proxywhen proxy use is relevant. - Any data-store reset, policy change, service restart, or update installation already performed.
- Whether healthy clients using the same policy and SUP succeed.
A Microsoft Q&A thread from 2016 shows why complete context matters: it records PopulateDataStore failed and the same search HRESULT, but the response asks for system and event-log details rather than claiming a diagnosed fix. If your evidence does not isolate a branch, ask Microsoft or your support provider to analyze the complete logs instead of applying an unsupported sequence of resets.
Also popular on Amazon
- 【Read before You Buy】 Note: This adapter is USB 2.0 version and cannot transmit HDM, VGA, or other video signals. Nevertheless, they are fully capable of charging devices,duplicating files, and can be seamlessly integrated with USB-C earphones, wireless network adapters, and SD card adapters.
- 【Easy to Use and Safe】Thanks to modern manufacturing techniques, we've made these adapters sufficiently compact so that they can remain inserted in your device without noticeable protrusion or inconvenience. This means you don't have to constantly plug and unplug them, reducing the likelihood of wear and misalignment, and making them more convenient to carry around.
- 【Reliable Quality】Engineered for enhanced durability, durable aluminum alloy shell material,get excellent wear resistance and heat dissipation,the male USB C and female USB connectors & the male USB and female USB C connectors are designed to be plugged and unplugged up to 20000 times. Provides data transfer, device charging, memory space expansion, and additional computer peripherals.
- 【Think more for you】Do you need to connect a USB-C-enabled device to an odd device that only has USB-A ports? Then these USB-A male to USB-C female adapters are made for you.Simply insert the adapter into the USB-A port on the device, and you can instantly connect your USB-C device to the device that originally didn't have the correct connection port.
- 【Trusted xiwxi Quality and Service】As a responsible brand seller, you will receive xiwxi's 12-month Quality assurance and lifetime friendly customer service, you're not just buying a product,you're investing in peace of mind with all-round quality and exceptional customer service.
Common mistakes when fixing 0x8007000E
- Reading the HRESULT literally:
E_OUTOFMEMORYis not proof of a RAM shortage. - Using only WUAHandler.log: it relays the agent’s result; WindowsUpdate.log often contains the useful preceding error.
- Resetting the data store first: a reset can be appropriate for component evidence, but the cited Microsoft list does not identify it as a universal 0x8007000E fix.
- Testing with a browser: browser proxy settings and WinHTTP settings may differ.
- Applying a legacy update broadly: the Windows 7/Server 2008 R2 direct-internet case is narrow and historical.
- Ignoring scope: one failing client and a site-wide failure require different investigation priorities.
- Deleting evidence: preserve logs and the renamed data directory until the incident is resolved.
What is the practical fix?
The practical fix is an evidence-led sequence: correlate WUAHandler and WindowsUpdate logs, verify the configured SUP and network path, check WinHTTP only when proxy or HTTP evidence exists, and perform a data-store reset only when component clues and current Microsoft guidance support it. Investigate the 1E legacy branch only when the operating system and deployment scenario match exactly. Because the reviewed sources do not establish a single code-specific cause, any article or script promising one universal remedy for every SCCM client with 0x8007000E is overstating the evidence.
Frequently Asked Questions
Can I safely ignore 0x8007000E if later scans succeed?
A one-time failure followed by successful scans may indicate a transient condition, but keep the original timestamps and logs until you know the deployment completed. Check whether required updates were actually evaluated and installed; a green client status alone may not prove that the failed scan’s products were processed.
Do these 3 things before closing this tab:
1Clear out junk files and repair common Windows errors2Fix the driver behind crashes, sound loss and screen glitches3Repair Windows errors before they cause bigger problemsDoes restarting the SMS Agent Host service repair this error?
Restarting the Configuration Manager client service can force a fresh request, but the supplied Microsoft evidence does not identify it as a specific remedy for this HRESULT. Treat a restart as a controlled reproduction step and inspect the new log sequence rather than assuming the problem is fixed.
Why can two clients with the same SCCM policy get different results?
They may resolve different SUP addresses, use different WinHTTP proxy paths, have different Windows Update datastore states, or run different Windows builds and client versions. Compare endpoint selection and the surrounding WindowsUpdate.log entries before comparing hardware.
What information should I send to Microsoft support?
Send synchronized WUAHandler.log and WindowsUpdate.log excerpts, OS and Configuration Manager versions, SUP URL and port, boundary-group assignment, proxy and DNS results, event logs, and a timeline of every repair attempted. Include a working client’s corresponding data when possible so support can distinguish shared-service failures from local state.