First identify what dropped. For a local relaxation file going to a network destination, -stream_loop -1 repeats the file, while FFmpeg’s FIFO pseudo-muxer can attempt to recover a failed output connection. For an HTTP source, use HTTP reconnect options before that source’s -i. Neither mechanism restarts FFmpeg after the process exits; that requires an external process supervisor.
Choose the recovery setting for the failure
“Restart” can mean several things. Pick the case that matches the break:
As an Amazon Associate I earn from qualifying purchases.
| What failed | Relevant mechanism | What it does not do |
|---|---|---|
| A local file reaches its end | -stream_loop -1, placed before the input’s -i |
It does not reconnect a publishing destination. |
| An HTTP input disconnects | HTTP protocol reconnect options, placed before that input’s -i |
These are not general network-output recovery switches. |
| A network output disconnects while FFmpeg is running | The FIFO pseudo-muxer’s output recovery options | It cannot relaunch FFmpeg if the process has exited. |
| The FFmpeg process exits | An external service manager or restart loop | In-process FIFO recovery cannot start a new process. |
FFmpeg options are position-sensitive: input options must precede the relevant -i. Check the installed build’s help and the official FFmpeg documentation index; the online documentation is regenerated nightly for the newest revision, which may differ from an installed version.
Quick wins for a faster PC:
Fix the driver behind crashes, sound loss and screen glitchesFind Drivers →Clear out junk files and repair common Windows errorsFree Scan →Scan for outdated or missing drivers - takes under a minuteDriver Scan →Local relaxation file to network output
For a local file intended to play continuously, combine input looping with output-side recovery. This is a template, not a verified drop-in command: replace the destination URL and format with values supported by your service, and confirm the selected options exist in your FFmpeg build.
#1 Best Overall
- 425VA/260W Standby Uninterruptible Power Supply (UPS): Uses simulated sine wave output to provide battery backup power and to safeguard home office, home entertainment including computers, gaming consoles, and broadband routers
- 8 NEMA 5-15R OUTLETS: Four battery backup & surge protected outlets; Four surge protected outlets; INPUT: NEMA 5-15P right angle, 45 degree offset plug with five foot power cord
- ADDITIONAL FEATURES: LED status light indicates Power-On and Wiring Fault, transformer-spaced outlets
- GREENPOWER UPS HIGH EFFICIENCY DESIGN: Reduces power consumption by utilizing a compact charger and power inverter to create an ultra-efficient backup power system for home and office use
- 3-YEAR WARRANTY – INCLUDING THE BATTERY; 75K USD Connected Equipment Guarantee; UL SAFETY CERTIFIED: Product has been tested in a UL certified lab and listed with UL as meeting or exceeding safety standards
ffmpeg -stream_loop -1 -re -i relaxation.mp4
-c:v copy -c:a copy
-f fifo
-attempt_recovery 1
-recovery_wait_time 5
-max_recovery_attempts 0
-fifo_format flv
'rtmp://DESTINATION/APP/STREAM_KEY'
-stream_loop -1is an input option and goes before-i; it loops the file indefinitely. It does not loop or reconnect the network publishing connection.-rereads the file at its native rate, commonly appropriate for live-paced file output. Confirm that behavior fits the source and destination.-f fifoselects the FIFO pseudo-muxer.-fifo_format flvspecifies the underlying output muxer in this example.-attempt_recovery 1enables attempts to recover output.-recovery_wait_time 5sets the wait between attempts here;-max_recovery_attempts 0requests unlimited attempts in builds that support this option.-c:v copy -c:a copyassumes the file’s codecs are compatible with the destination and the chosen muxer. If not, use codecs and encoding settings accepted by the destination instead of stream copy.
FFmpeg describes FIFO recovery as useful with network output because it can restart streaming transparently. That describes the feature’s aim, not a guarantee: a persistent outage, rejected credentials, incompatible output, or other error may prevent recovery. See the FIFO pseudo-muxer documentation.
Reconnect an HTTP input
When the relaxation stream itself is being read from an HTTP URL, place supported HTTP reconnect options before that source’s -i. For example:
Rank #2
- 1500VA/1000W PFC Sinewave Uninterruptible Power Supply (UPS): Uses sine wave output to provide battery backup power for Active PFC & conventional power supplies; Safeguards computers, workstations, network devices, and telecom equipment
- 12 NEMA 5-15R OUTLETS: 6 battery backup & surge protected outlets, 6 surge protected outlets; INPUT: NEMA 5-15P right angle, 45 degree offset plug with 5 foot power cord; 2 USB charge ports (1 Type-A, 1 Type-C) quickly charge phones and tablets
- MULTIFUNCTION, COLOR LCD PANEL: Displays immediate, detailed information on battery and power conditions; Color display alerts users to potential issues before they can affect critical equipment and cause downtime; Screen tilts up to 22 degrees
- AUTOMATIC VOLTAGE REGULATION (AVR): Corrects minor power fluctuations without switching to battery power; UL SAFETY CERTIFIED: Product has been tested in a UL certified lab and listed with UL as meeting or exceeding safety standards
- 3-YEAR WARRANTY – INCLUDING THE BATTERY; $500,000 Connected Equipment Guarantee; FREE PowerPanel Management Software (Download)
ffmpeg -reconnect 1 -reconnect_at_eof 1
-reconnect_streamed 1 -reconnect_delay_max 30
-i 'https://SOURCE/relaxation-stream' ...
Replace the example URL and trailing arguments with the real source and output settings. The HTTP protocol documentation describes these options:
Recommended Free Tools
-reconnect: reconnect after a disconnect before EOF.-reconnect_at_eof: treat EOF as an error and reconnect; useful for live or endless streams.-reconnect_on_network_error: reconnect for TCP/TLS errors during connection.-reconnect_on_http_error: reconnect for specified HTTP status codes or classes such as4xxand5xx.-reconnect_streamed: allow reconnect attempts for streamed, non-seekable inputs.-reconnect_delay_max,-reconnect_max_retries, and-reconnect_delay_total_max: limit retry delay, retry count, or total retry delay.-respect_retry_after: when enabled, honor the server’sRetry-Afterheader.
Choose bounds deliberately for the source and failure mode. These options cannot guarantee uninterrupted playback: recovery depends on the protocol, server, network, source availability, and installed FFmpeg build. Consult FFmpeg’s protocol documentation.
Rank #3
- 1500VA / 900W RELIABLE BACKUP POWER: The highest VA capacity available for home use; delivers short-term battery power to keep essential devices powered during blackouts, surges, and unexpected power interruptions
- TEN PROTECTED OUTLETS: Power your entire setup with 5 battery backup outlets for essential devices, and 5 surge-only outlets for peripherals. Plus built-in coaxial and Ethernet surge protection for added peace of mind
- AUTOMATIC VOLTAGE REGULATION (AVR): Corrects low voltage brownouts (88V+) and surges (+/-13%) without draining battery. Boosts or trims to stable 120V. Extends runtime for blackouts; Active PFC compatible for gaming PCs
- REPLACEABLE BATTERY & ENERGY STAR UPS: User-replaceable battery (APCRBC124, sold separately) for zero-downtime swaps. ENERGY STAR certified for 92%+ efficiency, cutting energy costs vs standard UPS units
- LCD DISPLAY PANEL: Features an intuitive LCD screen that displays real-time status information including battery charge level, estimated runtime, load capacity, and input voltage for easy monitoring of your power protection system
If FFmpeg itself exits
FIFO recovery operates while FFmpeg is running. If the process terminates, configure a separate supervisor—such as a service manager or a restart loop—to launch it again. A fresh invocation may start a local file from the beginning unless the command and source explicitly preserve position. The right supervisor configuration depends on your operating system and how you run FFmpeg; it is separate from FFmpeg’s input and output flags.
Check the destination and test the failure mode
- Confirm whether the source is a local file or HTTP input, and whether the failure is at input, output, or process level.
- Check your installed FFmpeg build’s supported options and the destination’s accepted protocol, container, codecs, and stream-key format. The official command-line reference explains option placement: FFmpeg command-line documentation.
- For a local file, verify that it plays correctly and that looping occurs before the publishing output. For HTTP, test the input reconnect options against the actual source.
- Test output recovery with the real destination and observe FFmpeg’s logs. A configuration can attempt retries without succeeding if the cause is persistent or unsupported.
- If the requirement includes recovery after an FFmpeg crash or exit, test the external supervisor separately from in-process output recovery.
Or let it run in the cloud
If your relaxation recording is for a YouTube channel, StreamNeo is a cloud alternative: upload the video, add your YouTube stream key, and go live. It loops uploaded videos, so your computer and home connection do not have to stay on. Each slot streams the upload as made, up to 4K 60fps, at one flat price per slot; it also attempts automatic recovery if YouTube drops the stream. The first day is free with no card. Monthly pricing is $9.99 per month.
Quick Recap
Best Value
- 12 NEMA 5-15R OUTLETS: Six battery backup & surge protected outlets; Six surge protected outlets (Three ECO controlled); INPUT: NEMA 5-15P right angle, 45 degree offset plug with five foot power cord
- MULTIFUNCTION LCD PANEL: Displays immediate, detailed information on battery and power conditions
- ECO MODE: When the UPS detects a computer is off or in sleep mode, it will automatically turn off power to computer peripherals connected to ECO mode outlets, reducing power usage and lowering energy costs
- 3-YEAR WARRANTY – INCLUDING THE BATTERY; $100,000 Connected Equipment Guarantee and FREE PowerPanel Personal Edition Management Software (Download)
Rank #4
- 1500VA/900W Intelligent LCD Uninterruptible Power Supply (UPS): Uses simulated sine wave technology to provide battery backup power to safeguard workstations, networking devices, and home entertainment equipment
- 12 NEMA 5-15R OUTLETS: Six battery backup & surge protected outlets; six surge protected outlets; INPUT: NEMA 5-15P plug with 6-foot power cord; USB charge ports (1 Type-A, 1 Type-C) quickly charge mobile phones and tablets
- MULTIFUNCTION, COLOR LCD PANEL: Displays immediate, detailed information on battery and power conditions; Color display alerts users to potential issues before they can affect critical equipment and cause downtime
- AUTOMATIC VOLTAGE REGULATION (AVR): Corrects minor power fluctuations without switching to battery power; UL SAFETY CERTIFIED: Product has been tested in a UL certified lab and listed with UL as meeting or exceeding safety standards
- 3-YEAR WARRANTY – INCLUDING THE BATTERY; 500,000 Connected Equipment Guarantee; FREE PowerPanel Personal Software (Download)
Start your free StreamNeo day.
Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon at the time of purchase will apply.