Quick wins for a faster PC:
Clear out junk files and repair common Windows errorsFree Scan →Fix the driver behind crashes, sound loss and screen glitchesFind Drivers →Repair Windows errors before they cause bigger problemsFix Now →In the reported OMA 15.0.13 fixture, a failed test gate returned a JSON decision of block with the reason Stop gate 'test' FAILED (reinforcement 1/5). The test process exited with status 1, even though the oma hook run command itself exited 0. The hook’s exit code alone therefore did not mean the tests passed.
What the failed gate response means
The response in this manual Stop-hook run carried the failure in its JSON decision: "decision":"block". Its accompanying reason identified the gate and reported reinforcement 1/5. Those fields—not the hook command’s zero exit status—showed that the configured test gate had failed.
As an Amazon Associate I earn from qualifying purchases.
There were two separate process results: the configured test process exited 1, while the hook command exited 0. Read the gate response and the test process status as distinct signals; do not treat the hook command’s status as a substitute for the test result.
Why the fixture test failed
The fixture checked whether an item was expired at its expiry time. The intended boundary condition was that it should count as expired when now === expiresAt, but the implementation used now > expiresAt. At equality, that comparison returned false, so the boundary test failed.
The reported test output included not ok 2 - at expiry: expired, # pass 2, and # fail 1. A manual call to OMA’s Stop hook reran the configured test script and returned the block decision.
What changed after the fix
The fixture comparison was changed from > to >=, so an item was treated as expired at equality as intended. The rerun reported three passes and zero failures.
On the next Stop call, the gate ran and returned empty stdout. The fixture then recorded gate.passed, followed by session.ended with reason completion_gate_passed.
The Tool Desk
Outbyte Driver Updater FREEScan for outdated or missing drivers - takes under a minuteDriver Scan →Outbyte PC Repair FREERepair Windows errors before they cause bigger problemsFix Now →Scope of this example
This is a report of a local OMA 15.0.13 fixture with manually invoked hooks, not a recorded autonomous-agent session or a production incident. It shows the configured gate’s behavior on the fixture’s tests; it does not establish general correctness or confirm that current OMA source or documentation behaves the same way.
The indexed article gives this reproduction command: python3 reproduce.py --oma-source /path/to/oh-my-agent --output /path/to/new-demo-run. It says the script requires Python 3, Git, Node, and Bun. The evidence for the result comes from the indexed article text; the article page could not be independently opened, and no official source was available to verify whether this behavior remains current.
Quick Recap
Best Value
Rank #4