October DealsAmazon USOctober deal check: compare before you payAmazon US: current deals, useful picks and tech finds.Check DealsWindows FixRecommendedWindows errors stealing your time? Find the fix fastScan stability, cleanup and performance issues.Fix NowOctober DealsAmazon USDeal season is back - check today's better picksAmazon US: current deals, useful picks and tech finds.See Picks×
Skip to content
World desk8 min

What to Do When a Software KVM Cannot Detect Another Computer

A software KVM usually fails to detect a second computer because of network reachability, incorrect roles or identity, firewall rules, discovery, or trust settings. Follow this product-specific troubleshooting sequence.
Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

If a software KVM cannot find the other computer, troubleshoot it as a chain of prerequisites rather than as one mysterious fault. Confirm that both machines are on the same reachable local network, running compatible software, assigned the correct server/primary and client roles, and using the right computer name or security key. Then check firewall permissions, product-specific ports, discovery, and trust prompts.

A computer that appears in the app is not necessarily ready to share input. Screen layout, client names, Scroll Lock, and the selected primary computer determine whether the keyboard and mouse actually cross from one display to the next.

As an Amazon Associate I earn from qualifying purchases.

First, identify which stage is failing

“Cannot detect” can describe several different failures. Separating them prevents you from changing unrelated settings.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.
  • Nothing appears: the computers may be on different networks, blocked by a firewall, using incompatible products, or unable to complete local discovery.
  • The computer appears but will not connect: check the host name or IP address, security key, server/client assignment, ports, and trust prompts.
  • It connects but the pointer will not cross: inspect the configured screen arrangement, client names, primary/server role, and Scroll Lock.
  • The connection repeatedly times out: treat it as a reachability, credential, or firewall problem rather than a display-layout problem.

A software KVM normally shares a physical keyboard and mouse over the local network. It does not automatically transmit the other computer’s screen. Synergy’s architecture documentation describes keyboard and mouse sharing, not video-KVM functionality.

#1 Best Overall
Cable Matters 10Gbps Snagless Cat 6 Ethernet Cable, 25ft, Black
  • High-Performance Connectivity: This Cat 6 ethernet cable is designed for superior performance, with a 24 AWG copper wire core. It provides universal connectivity as an ethernet cord for LAN network components such as PCs, servers, printers, routers, and more, ensuring reliable and fast network connections
  • Advanced Cat6 Technology: Experience Cat6 performance with higher bandwidth at a Cat5e price. This network cable is future-proof, ready for 10-Gigabit Ethernet and backwards compatible with any existing Cat 5 cable network. It meets or exceeds Category 6 performance according to the TIA/EIA 568-C.2 standard
  • Reliable Wired Network Solution: Known variously as a Cat6 network cable, ethernet cable Cat 6, or Cat 6 data/LAN cable, this RJ45 cable offers a more secure and reliable connection than wireless networks. It's ideal for internet connections that demand consistency and security
  • Durable and Secure Design: The connectors of this ethernet cable feature gold-plated contacts and strain-relief boots for enhanced durability. Bare copper conductors not only improve cable performance but also comply with communication cable specifications
  • High-Speed Data Transfer: With up to 550 MHz bandwidth, this ethernet cord is ideal for server applications, cloud computing, video surveillance, and streaming high-definition video. It also supports Power over Ethernet (PoE, PoE+, PoE++) for powering devices like IP cameras, VoIP phones, and wireless access points, ensuring fast and reliable network performance.

1. Confirm the product, versions, and roles

Use the same product on every computer

Install the same product and, where the product requires it, the same major version on each participating machine. Synergy’s current troubleshooting guidance covers Synergy 3 version 3.7.2 and Synergy 1 version 1.21.4 as checked on October 3, 2026. Instructions and port requirements differ between Synergy 1, Synergy 3, Barrier, and Mouse Without Borders, so do not apply one product’s settings to another.

Assign the keyboard-and-mouse computer correctly

In Synergy 1, the computer with the physical keyboard and mouse is the server; every other machine is a client. Synergy 3 calls the sharing computer the primary. If the roles are reversed, a peer may be visible while input sharing still fails.

Mouse Without Borders uses a different setup: generate a security key on the first computer, then enter that key and the first computer’s host name on the second computer. The host name and key must match exactly.

Free tools Windows power users keep installed

One-click scans. No signup required.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

2. Prove that the computers can reach each other

Check the local network

Both computers must be connected to the same reachable local network, either by Wi-Fi or Ethernet. Guest Wi-Fi, client-isolation settings, separate VLANs, and some corporate networks can prevent devices from talking even when they have internet access. Confirm the network name and connection status on both machines before changing KVM settings.

Rank #2
Jadaol Cat6/Cat6A Ethernet Cable 50FT Flat with Clips 10Gbps Network, White
  • Cat 6 performance at a Cat5e price but with higher bandwidth
  • High Performance Cat6, 30 AWG, RJ45 Ethernet Patch Cable provides universal connectivity for LAN network components such as PCs,computer servers,printers,routers,switch boxes,network media players,NAS,VoIP phones
  • Jadaol cat6 standard cable support Cat8 and Cat7 network and provides performance of up to 250 MHz 10Gbps and is suitable for 10BASE-T, 100BASE-TX (Fast Ethernet), 1000BASE-T/1000BASE-TX (Gigabit Ethernet) and 10GBASE-T (10-Gigabit Ethernet)
  • UTP(Unshielded Twisted Pair) patch cable with RJ45 gold-plated Connectors and are made of 100% bare copper wire, ensure minimal noise and interference
  • The unique flat cable shape allows for a cleaner and safer installation. You can easily and seamlessly make the cable run along walls, follow edges & corners or even make it completely invisible by sliding it under a carpet.

Test by name and by address

Use the peer’s computer name or IP address to test basic reachability. Barrier’s troubleshooting guidance gives these examples:

ping <hostname or IP>
Test-Connection -ComputerName <hostname or IP>

Run the first command in Windows Command Prompt or the second in PowerShell, replacing the placeholder with the server or primary computer’s actual name or address. A failed test points to a network path or name-resolution problem, although a blocked ping alone does not prove that the KVM connection itself is broken; some networks and firewalls suppress ICMP replies.

Prefer a stable identity

For Synergy 1, Symless recommends entering the server’s computer name rather than relying on an address assigned by the router. A router can change a DHCP-assigned IP address after a reconnect or lease renewal. If the name does not resolve, test the current IP address temporarily to distinguish name-resolution trouble from a wider connection failure.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

A wired Ethernet connection can be a useful diagnostic when Wi-Fi is unstable. It will not correct a wrong server name, a mismatched key, or a blocked port, and it is not required when the wireless network is configured correctly.

Rank #3
Sale
UGREEN Cat 8 Ethernet Cable 6FT, High Speed Braided 40Gbps 2000Mhz Network Cord Cat8 RJ45 Shielded Indoor Heavy Duty LAN Cables Compatible with Gaming PC PS5 PS4 PS3 Xbox Modem Router 6FT
  • 40 Gbps 2000 Mhz High Speed: The Cat 8 ethernet cable support max. 40 Gbps data transfer and 2000 MHz Brandwith, ideal for gaming and streaming, greatly improving upload and download speed, sound, image and resolution quality
  • Excellent Anti-interference: The ethernet cable comes with 4 shielded foiled twisted pairs (F/FTP), pure copper core and gold-plated RJ45 connector, reducing interference, noise and crosstalk, making network speed faster and more stable
  • Marvelous Durability: Internet cable wrapped with quality cotton braided cord, which makes the LAN cable stronger and more durable. The test proves that this internet cable can be bent at least 10000 times without broken, very suitable for long-term use
  • PoE Supported: All lengths of ethernet cord can support the PoE power supply function except 65ft. You don't need additional power supply when installing a PoE camera, which is very convenient and safe
  • Wide Compatibility: With the RJ45 Connector, network cable can be perfectly compatible with computers, laptops, modems, routers, PS5, X-Box and other networking devices. It can also be fully backward compatible with Cat7, Cat6e, Cat6, Cat5e, Cat5

3. Check firewall permissions and ports

Allow the application on the local network

Permit the KVM application, and its background service when the product uses one, through the host firewall on the computers that need to communicate. Windows Synergy installers normally create the required rules. macOS, Linux, and third-party security firewalls may require an explicit allow rule.

Mouse Without Borders exposes an Add a firewall rule setting. Use that product control instead of creating broad, unrelated exceptions. Apply the narrowest rule that permits local-network communication, and do not expose these services to the public internet.

Use the ports for the product you actually installed

Product or service Port and protocol Purpose
Synergy Core (Synergy 1 and Synergy 3) TCP 24800 Main Synergy connection
Synergy 3 TCP 24802 Settings synchronization
Synergy 3 TCP 24804 Auto-discovery
Synergy 3 local service TCP 24803 on 127.0.0.1 Local-only communication; it does not require a network firewall opening
Mouse Without Borders Not stated in the cited guidance Use its firewall-rule control and product documentation rather than Synergy port numbers
Barrier Not stated in the cited guidance Validate reachability, the running processes, and the firewall for the Barrier installation

Do not assume that opening TCP 24800 will make every software KVM work. Synergy 3’s discovery and synchronization use additional ports, while other products use their own mechanisms.

What’s actually slowing this PC down?

Pick the symptom - the matching free tool is one click away.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

4. Handle discovery separately from manual connection

When Synergy 3 shows only one computer

Synergy 3 discovers peers on the local network using multicast DNS by default. Multicast traffic can be filtered by a router, access point, VPN, or firewall even when ordinary unicast traffic works. If auto-discovery fails, open Manage computers and choose Manually add computer. Enter the peer’s correct name or address, then retry the connection.

Rank #4
Sale
Cable Matters 10Gbps 5-Pack Snagless Cat 6 Ethernet Cable, 6ft, Black
  • High-Performance Connectivity: This Cat 6 ethernet cable is designed for superior performance, with a 24 AWG copper wire core. It provides universal connectivity as an ethernet cord for LAN network components such as PCs, servers, printers, routers, and more, ensuring reliable and fast network connections
  • Advanced Cat6 Technology: Experience Cat6 performance with higher bandwidth at a Cat5e price. This network cable is future-proof, ready for 10-Gigabit Ethernet and backwards compatible with any existing Cat 5 cable network. It meets or exceeds Category 6 performance according to the TIA/EIA 568-C.2 standard
  • Reliable Wired Network Solution: Known variously as a Cat6 network cable, ethernet cable Cat 6, or Cat 6 data/LAN cable, this RJ45 cable offers a more secure and reliable connection than wireless networks. It's ideal for internet connections that demand consistency and security
  • Durable and Secure Design: The connectors of this ethernet cable feature gold-plated contacts and strain-relief boots for enhanced durability. Bare copper conductors not only improve cable performance but also comply with communication cable specifications
  • High-Speed Data Transfer: With up to 550 MHz bandwidth, this ethernet cord is ideal for server applications, cloud computing, video surveillance, and streaming high-definition video. It also supports Power over Ethernet (PoE, PoE+, PoE++) for powering devices like IP cameras, VoIP phones, and wireless access points, ensuring fast and reliable network performance.

When Synergy 1 cannot place a client

In the Synergy 1 server configuration, add each client in the screen layout grid. The configured client name must match the actual Synergy name reported by that computer. A client with a spelling, capitalization, or punctuation mismatch can be running and reachable yet still be rejected by the server.

When manual setup succeeds but discovery does not

This result narrows the fault to discovery rather than basic connectivity. Keep the manual entry if it is reliable, then investigate multicast filtering, VPN routes, and local firewall rules. Discovery is a convenience; a successful manual connection demonstrates that the core path can work.

5. Verify names, keys, and trust prompts

Synergy identity and TLS fingerprints

Synergy 1 Pro or business installations may show a TLS fingerprint prompt the first time computers connect. Compare the fingerprint displayed on both computers and accept only matching values. If the client does not trust the server fingerprint, the connection is refused even when the machines can ping each other.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

Mouse Without Borders credentials

Check both the host name and security key. Mouse Without Borders can display states such as InvalidKey and Timeout; the former points toward a credential mismatch, while the latter indicates that the peer did not complete a connection in time. Regenerate and re-enter the key only after confirming that the host name is correct.

Best Value
Sale
Ultra Clarity Cables Cat6 Ethernet Cable 100 FT 10Gbps Long Cable, Black
  • High Performance Cat6 Cable - The Cat6 ethernet cables 100ft supports frequencies of up to 500 MHz and high-speed 10GB internet connection for LAN network applications such as PCs,computer servers,printers,routers,switch boxes,network media players,NAS,VoIP phones and more, while remaining fully backward compatible with your existing network.
  • Outdoor&Indoor Ethernet Cable - The cat 6 ethernet patch cable features 8 solid copper conductors 24 AWG. Each of the 4 unshielded twisted pairs (UTP) are separated by a PE cross insulation to isolates pairs and prevent crosstalk and covered by a 5.8mm PVC jacket with RJ45 connectors and gold-plated contacts. The molded strain relief boots help avoid snags that will damage your cables. They are molded for flexibility and resist common wear and tear.
  • Lan Cable with RJ45 - UTP(Unshielded Twisted Pair) patch cable with RJ45 gold-plated Connectors, this cat6 cable support Cat8 and Cat7 network and provides performance of up to 500 MHz 10Gbps and is suitable for 10BASE-T, 100BASE-TX (Fast Ethernet), 1000BASE-T/1000BASE-TX (Gigabit Ethernet) and 10GBASE-T (10-Gigabit Ethernet)
  • High Quality Control - are designed with extremely well-matched components for outstanding uniform impedance and very low return loss, providing lower crosstalk, and a higher signal-to-noise ratio. Each Cat 6 internet cable 6 ft goes through rigorous testing to ensure a secure wired internet connection with exceptional speed and reliability.
  • Support – Cat6 Ethernet cable with CM grade PVC jacket complies with TIA/EIA 568-C.2, is ETL verified and RoHS compliant. If an item is defective or breaks within a year, we will issue a replacement. For questions or concerns please contact our friendly, USA-based customer Support team.

Barrier trust

Barrier’s guidance likewise requires the client to trust the server fingerprint. A trust failure is different from a missing route: resolve the fingerprint prompt or stored trust decision before changing network topology.

Independent reader supportYour contribution helps us test, update, and keep practical guides available for everyone.Support on Ko-Fi

6. If the peer is visible but input does not move

Check the screen arrangement

Configure the primary/server computer and place the client on the correct side of it. The pointer crosses only at an edge that is adjacent in the layout. If the second display is physically to the left but configured to the right, moving the pointer toward the real-world position will appear to do nothing.

Confirm the sharing role and client name

Ensure the computer with the physical keyboard and mouse is selected as the Synergy primary/server. In Synergy 1, verify again that every grid entry exactly matches the corresponding client name. A visible connection does not override an incorrect layout or identity.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

Release a locked pointer

Synergy’s troubleshooting checklist calls out Scroll Lock. If Scroll Lock is enabled, the cursor can remain locked to one computer. Turn it off and test each configured screen edge again.

Refresh Mouse Without Borders

Use the device layout and refresh the connections when Mouse Without Borders reports that a link was lost. Confirm that the machines still have the intended positions after reconnecting.

7. Reduce variables and restart in a controlled order

  1. Temporarily test without a VPN, if your environment permits it. Synergy’s troubleshooting checklist specifically recommends checking VPN software because it can alter routes or block local discovery. Do not remove a required corporate VPN without authorization.
  2. Close and reopen the KVM application on every participating computer after changing names, roles, firewall rules, or discovery settings.
  3. Recheck the ping or PowerShell test and then retry the KVM connection using the confirmed host name or address.
  4. Restart the computers if the service remains stuck after configuration changes. This clears stale background processes and network state.
  5. Undo one change at a time if the problem began after a firewall, VPN, network, or version change. Record which setting restored the connection.

Do not disable every security control as a troubleshooting shortcut. Use a scoped application or port allowance on the local network, then remove temporary exceptions that are no longer needed.

Product-specific decision guide

Need Synergy 1 Synergy 3 Mouse Without Borders Barrier
Operating systems documented here Windows, macOS, Linux Windows, macOS, Linux Windows through PowerToys Use the project’s platform guidance
Initial configuration Server/client roles and a configured screen grid Primary computer, auto-discovery or manual addition Host name plus security key Server/client setup and trusted fingerprint
Discovery approach Configured clients Multicast DNS by default; manual addition available Key-and-host pairing Validate server reachability and processes
Security check TLS fingerprint prompt may appear Product trust and local service rules Security key; InvalidKey and Timeout states Trusted server fingerprint
Important caution Client names must match exactly Auto-discovery ports differ from the main connection Do not substitute Synergy ports Use Barrier-specific troubleshooting

What the symptoms usually mean

  • Ping by IP fails: investigate Wi-Fi isolation, routing, Ethernet/Wi-Fi state, or a firewall before editing KVM layouts.
  • Ping by IP works but the name fails: troubleshoot name resolution or use the confirmed address while you repair naming.
  • Synergy 3 manual addition works but auto-discovery fails: multicast DNS or discovery traffic is being filtered.
  • Mouse Without Borders says InvalidKey: recheck or regenerate the security key; this is not primarily a screen-layout issue.
  • The peer is listed but the pointer stops at the edge: inspect primary/server selection, adjacency, client naming, and Scroll Lock.
  • It connected before a VPN or firewall change: compare routes and scoped allow rules, then restart the affected service.

When to stop troubleshooting the KVM

If both computers can reach each other, the correct product and roles are selected, names or keys match, required local firewall rules are present, trust prompts are accepted, and the layout is correct, the remaining fault may be product- or platform-specific. Synergy’s guidance asks Linux users to check current desktop and Wayland support details because capabilities can vary by desktop environment. Capture the product name and version, operating systems, exact error state, ping results, and which manual or discovery step failed before seeking support. That information distinguishes a network-path problem from a client-service or compatibility problem.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon at the time of purchase will apply.

Leave a Reply

Your email address will not be published. Required fields are marked *

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

More from the Wire

  1. World desk4 min
    How to Spot an AI Voice Scam Before Sending MoneyDon’t rely on how a caller sounds. Pause, call back through a known number, and verify the emergency with another trusted person before sending money.
  2. Mountain View desk4 min
    Google’s SynthID Detector: How to Check AI-Generated Images, Video and AudioGoogle’s SynthID Detector looks for an embedded watermark in supported images, video and audio. Here is what its results do—and do not—show.
  3. Redmond desk20 min
    How to create a link to File or Folder in Windows 11Windows 11 gives you several ways to point to a file or folder without moving or duplicating it. You can create a desktop shortcut,…
Recommended PC Tool
Recommended PC Tool
Outdated Drivers Are Slowing You DownFree scan - exact matches
PC Slower Than It Used to Be?Free scan - under a minute

Two free Windows tools

One Free Minute Could Fix That PC

Before you go - each of these free tools takes about a minute and tackles what quietly slows a Windows PC down.

Special offer. View Outbyte info, uninstall instructions, EULA, and Privacy Policy.