October DealsAmazon USOctober deal check: compare before you payAmazon US: current deals, useful picks and tech finds.Check DealsSlow PC?RecommendedPC slow today? Run a repair scan before it gets worseResolve common Windows issues and optimize system performance.Scan NowOctober DealsAmazon USDeal season is back - check today's better picksAmazon US: current deals, useful picks and tech finds.See Picks×
Skip to content
World desk12 min

How to Choose a Server CPU for Running AI Agents at Scale

A role-based method for choosing CPUs for sandbox fleets, GPU hosts and agent service tiers, with benchmark interpretation, platform trade-offs and a production testing workflow.
Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

Choose the CPU for the work surrounding model inference, not for a headline core count. Agent platforms spend CPU cycles on orchestration, tool processes, retrieval, memory and state, databases, API services, sandbox creation, serialization, networking and storage. A sandbox-heavy fleet, a latency-sensitive GPU host and a general service tier therefore need different CPUs.

The reliable method is to map those roles, replay representative traces at your target concurrency, measure throughput and tail latency, and compare complete server configurations for memory, I/O, software fit, power and support. No single CPU SKU can be named without your framework, workload trace, service-level objectives and server constraints.

As an Amazon Associate I earn from qualifying purchases.

What the CPU does in an AI-agent system

An agent request is usually a sequence of model calls and computer-side actions. The CPU may schedule the next step, launch a tool, enforce a sandbox policy, serialize arguments, query a database, retrieve documents, update memory, call an API, parse a response and record state. On an inference server it also handles request admission, runtime control, host-to-accelerator transfers and other control-plane work.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

That makes “AI workload” an incomplete description for procurement. Two deployments can use the same model while stressing their CPUs in opposite ways:

#1 Best Overall
Elebase USB to USB C Adapter for iPhone 18 Pro Max,USBC Car Charger Adapter | 4Pack Type C Female to A Male Cable Converter for Apple Duo 17 16 15 14 Plus,iWatch Watch 12 11 10,iPad 9 8 Air,Airpods 5 4
  • Read Before You Buy — No Video Output: These adapters support charging and USB 2.0 data transfer, but cannot transmit video signals. Except for standard USB webcams (which use USB data only), they are not compatible with HDMI/DisplayPort cables, video-capable USB-C hubs, or docking stations with video output.
  • Convert USB-A Ports to USB-C: Designed to connect USB-C earphones, cables, flash drives, card readers, and other USB-C accessories to standard USB-A ports. Plug-and-play with no drivers or software required.
  • Aluminum Alloy Housing: Built with a sturdy aluminum alloy shell that aids in heat dissipation and protects against daily wear and scratches. Designed to maintain a stable and secure connection.
  • Compact & Travel-Friendly: The ultra-compact design allows the adapter to stay plugged into your device without blocking adjacent ports or adding bulk, reducing wear and tear on your original USB ports.
  • 12-Month Warranty: Backed by a 12-month manufacturer warranty for peace of mind. Designed to meet strict quality control standards for reliable everyday performance.
  • Sandbox and tool-execution fleets create many short-lived or isolated processes. They need useful aggregate throughput, enough memory for concurrent environments and predictable startup and teardown latency.
  • GPU host nodes must keep accelerators fed and respond quickly to runtime and scheduling events. Host-to-GPU and network I/O, memory behavior and per-thread responsiveness can matter more than maximum socket throughput.
  • General-purpose service nodes run APIs, retrieval, caches, databases and queues. Their bottleneck may be storage wait, synchronization or memory bandwidth rather than arithmetic capacity.

Start by deciding which of these roles a server will perform. A CPU that is excellent for one role can be wasteful or inadequate for another.

Define “scale” before selecting a processor

“At scale” should be a measurable operating point. Write down the metric that determines whether the system succeeds, then attach a target and a time window to it. Common definitions include:

  • simultaneous agents or active workflows;
  • tool calls per second;
  • completed workflows per hour;
  • time to first response and end-to-end completion latency;
  • p95 or p99 latency under a stated concurrency;
  • a rack power, cooling or server-count limit; and
  • availability, isolation and recovery requirements for failed sandboxes.

Also record the agent framework, language runtimes, container or virtual-machine technology, database and vector-search choices, accelerator type, operating system, compiler and runtime versions, and whether work is spread across one host or several tiers. These details determine which CPU features are useful and which benchmark is representative.

Free tools Windows power users keep installed

One-click scans. No signup required.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

A CPU-selection workflow that survives production

1. Map CPU roles and service boundaries

Draw the execution path for one workflow. Mark every component that runs on a CPU node, beside an accelerator or inside an isolated sandbox. Include ingress, authentication, scheduling, model gateway, retrieval, tool workers, state storage, queues, logging and telemetry. AMD describes three useful planning categories—scaling agent sandboxes, maximizing AI host-node throughput and powering general-purpose workloads—while Intel highlights orchestration, tool execution, memory access, storage and runtime management. Use those categories to assign an explicit role to each server pool.

Do not hide a database or retrieval service in an “agent” average. If it is on the same host, its CPU, memory and I/O demand belongs in the host test. If it is a separate tier, measure the network and queueing behavior between tiers.

2. Capture a representative trace

Use production telemetry with sensitive data removed, or replay a trace that preserves the timing and fan-out of real requests. A useful trace records model calls, tool type, payload size, retries, sandbox lifetime, retrieval volume, database operations and cancellation behavior. Synthetic loops that call a model repeatedly can miss the CPU work that actually limits an agent service.

At each concurrency level, record:

  • completed workflows and tool calls per second;
  • median, p95 and p99 latency for the whole workflow and each stage;
  • CPU utilization by process and by core, run-queue length and throttling;
  • memory capacity used, bandwidth pressure, page faults and NUMA locality;
  • storage and network wait, packet rates and queue depth;
  • sandbox create, ready and delete times;
  • accelerator utilization and host-to-device transfer wait; and
  • error, retry and timeout rates.

Run long enough to expose thermal, garbage-collection, cache and queueing effects. A short burst can make a CPU look fast while sustained service throughput falls after power or memory limits are reached.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.
Rank #2
Sale
Anker USB-C Hub, 5-in-1 USB Hub for Laptops, 4K HDMI Multiport Adapter
  • 5-in-1 USB-C Hub: Experience comprehensive connectivity featuring a Power Delivery input, two USB-A 2.0 ports, a USB-A 3.0 port, and an HDMI port. (Note: The USB-C power delivery input port is only for connecting an external wall charger to power your laptop and cannot power peripheral devices.)
  • 90W Pass-Through Charging: Achieve optimal charging with 90W pass-through power to your laptop, supported by a total input of 100W, with the hub reserving 10W for operational efficiency. (Note: Wall charger not included.)
  • Quick Data Transfers: Accelerate your productivity with rapid data transfers using a high-speed 5Gbps USB 3.0 port and two 480Mbps USB 2.0 ports.
  • 4K HDMI Display: Enhance your visual experience with a hub capable of delivering 4K resolution at 30Hz in both mirror and extend modes. Please note that this hub is compatible with MacBook (macOS 12 and newer), Windows 10 and 11, ChromeOS, and laptops equipped with DP Alt Mode and Power Delivery. Note: This device is not compatible with Linux.
  • What You Get: Anker USB-C Hub (5-in-1, 4K HDMI), welcome guide, 18-month warranty, and our friendly customer service.

3. Identify the limiting stage

If GPUs are idle while requests wait in the host, test scheduler responsiveness, host-to-accelerator I/O, networking and per-thread performance. If completed workflows stop increasing as you add agents, inspect memory bandwidth, synchronization, sandbox overhead and storage wait before buying more cores. If retrieval or transactions dominate, benchmark those systems with the same indexes, cache state and durability settings used in production.

This diagnosis matters because a CPU specification cannot repair every bottleneck. More cores do not fix a saturated storage device, a locked database, a NUMA-misaligned queue or an under-sized network path.

4. Set acceptance criteria

Turn the trace into a pass/fail test. Specify the target concurrency, minimum completed workflows per second, p95 or p99 latency ceiling, error rate, memory headroom, accelerator utilization and maximum system power. Include a degradation test: increase concurrency until the first service-level objective fails, then record the sustainable operating point. A candidate that wins a peak-throughput chart but violates latency or power limits is not the better platform.

5. Compare complete, matched platforms

Compare servers rather than bare CPU names. Hold software versions, firmware, power policy, memory population, accelerator configuration, storage devices and network adapters constant where possible. If a result uses more memory channels, faster storage or a different accelerator, disclose that difference; it is not a CPU-only comparison.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

Evaluate each candidate on the following axes:

Axis What to measure Why it changes the decision
Workload throughput Completed workflows, tool calls or transactions per second at target concurrency Shows useful work, not an abstract core count
Tail latency p95/p99 stage and end-to-end latency while the service is busy Coordination and interactive agents are sensitive to outliers
Per-thread performance Serial orchestration steps, queue handling and control-plane response Some phases cannot use all cores
Parallel capacity Core and thread count under sustained power and thermal limits Determines how many sandboxes or workers can run concurrently
Memory Capacity, bandwidth, cache behavior and NUMA locality Paging or remote-memory access can erase core gains
I/O PCIe lanes, accelerator transfers, network and storage queueing Tools, retrieval and GPU hosts often wait on I/O
Software fit OS, runtime, container, compiler, driver and instruction-set support Compatibility and operational risk affect real throughput
Platform economics Power, cooling, rack density, purchase price and support Capacity may be limited by the rack rather than the socket

How to prioritize specifications

Core count and per-core speed

Core count is valuable when independent tool processes, retrieval jobs or sandboxes run in parallel. It is less useful when a workflow spends much of its time in serial coordination, lock contention or network wait. Per-thread performance influences scheduler decisions, queue handling and latency-sensitive runtime phases. Measure both aggregate throughput and single-request responsiveness; never infer either from core count alone.

Simultaneous multithreading can improve utilization for suitable mixes, but it does not double physical compute capacity. Test with your runtime, especially when agents share caches or when isolation policies pin workloads to specific CPUs.

Memory capacity, bandwidth and NUMA

Size memory for the resident working set: model-serving runtime overhead, agent state, retrieval indexes, databases, page cache, container images and the peak number of sandboxes. Leave headroom for bursts and rolling deployments. Once the system pages, CPU comparisons become comparisons of storage latency.

Rank #3
Sale
Anker USB C Hub, 7in1 Multi-Port USB Adapter, 4K@60Hz USBC to HDMI Splitter
  • Sleek 7-in-1 USB-C Hub: Features an HDMI port, two USB-A 3.0 ports, and a USB-C data port, each providing 5Gbps transfer speeds. It also includes a USB-C PD input port for charging up to 100W and dual SD and TF card slots, all in a compact design.
  • Flawless 4K@60Hz Video with HDMI: Delivers exceptional clarity and smoothness with its 4K@60Hz HDMI port, making it ideal for high-definition presentations and entertainment. (Note: Only the HDMI port supports video projection; the USB-C port is for data transfer only.)
  • Double Up on Efficiency: The two USB-A 3.0 ports and a USB-C port support a fast 5Gbps data rate, significantly boosting your transfer speeds and improving productivity.
  • Fast and Reliable 85W Charging: Offers high-capacity, speedy charging for laptops up to 85W, so you spend less time tethered to an outlet and more time being productive.
  • What You Get: Anker USB-C Hub (7-in-1), welcome guide, 18-month warranty, and our friendly customer service.

Bandwidth matters when many workers scan data, serialize large payloads or run vector and data-processing stages. On multi-socket systems, placement matters as well. Keep a worker, its queue and its data close to the memory controller and I/O device it uses, or measure the penalty of remote NUMA access. Match memory channels and population across test systems; an under-populated candidate can look slower for reasons unrelated to its processor.

What’s actually slowing this PC down?

Pick the symptom - the matching free tool is one click away.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

Cache and synchronization

Agent runtimes repeatedly touch queues, registries, token buffers and shared state. Cache size and cache locality can affect these patterns, while locks and atomics can make a high-core-count system scale poorly. Include contention in your trace: run the same workflow with one worker, then increase concurrency and plot throughput and tail latency. A flattening curve signals a shared resource that more cores will not solve.

Storage and networking

Tool execution may create files, pull images, write logs and access secrets. Retrieval and databases generate small random reads, writes and network round trips. Measure queue depth, I/O wait and packet processing with realistic payloads. Verify PCIe lane allocation so that accelerators, high-speed network cards and NVMe devices do not silently share a constrained link.

For distributed agents, network latency and connection tracking can dominate the CPU time of an individual step. Test the full path, including TLS, service mesh, retries and cross-zone traffic if those are part of the design.

Instruction sets and software compatibility

Confirm that your operating system, hypervisor, container base images, language runtimes, database extensions, cryptographic libraries and observability agents support the candidate architecture. Validate compiler flags and binary distribution policies before procurement. A theoretical vector advantage has no value if the production build cannot use it or if a dependency falls back to a slower implementation.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

Role-specific CPU priorities

Sandbox and tool-execution nodes

Prioritize sustained multi-core throughput at realistic concurrency, memory capacity, isolation overhead and sandbox startup latency. Measure create, ready, execute and delete operations separately; a CPU that runs a tool quickly may still lose if environment startup dominates. Pinning, cgroup limits and filesystem choice can change results, so keep those settings identical across candidates.

Intel publishes a sandbox comparison using a CubeSandbox create/delete test and a latency threshold. Treat that as a reminder to test sandbox operations directly, not as a universal CPU score or a promise for a different sandbox implementation.

Rank #4
Sale
UGREEN USB to USB C Adapter Combo 4-Pack, 10Gbps USB C Converter Space Gray
  • Dual Converters, Infinite Potential:Includes 2× USB C male to USB A female adapters and 2× USB A male to USB C female adapters. Perfect for a wide range of uses—tablets with Bluetooth keyboards, expand USB ports on macbook, and more. Two different converters for all your daily needs
  • Next-Level 10Gbps & 3A Charging: No more slow 480Mbps, this usb to usb c adapter has a transfer speed of up to 10Gbps, allowing you to do more transferring in less time. This usb adapter fits both USB A and USB C charger, supporting up to 3A fast charging
  • Upgraded Exquisite Craftsmanship: With an aluminum alloy housing and metal connector, the usbc to usb adapter is extremely durable and sturdy. Rigorously tested to withstand more than 10,000 times of plugging and unplugging, ensuring long-lasting performance
  • Broad Compatible: The usb c to usb adapter widely supports all USB C/ USB A devices like laptops, tablets, cellphones, car chargers, and phone chargers. Such as compatible with MacBook Pro/Air 2023/2022, Thunderbolt 4/3 Devices,Apple MagSafe Watch 9/8/7/SE/Ultra, iPad Pro 2022/2021, Samsung Galaxy S23/S20/S10, and iPhone 17/16/15 Pro. Plug and play
  • Please Note: To reach 10Gbps speed, keep the cable under 3.3 ft. For USB A Male to USB C adapters, try flipping the USB C connector. USB C Male to USB A adapters support bidirectional 10Gbps transfer within 3.3 ft

GPU host nodes

The host CPU should keep accelerators supplied and the control plane responsive. Test request dispatch, batching, host-to-device copies, networking, runtime threads and CPU-sensitive collective operations. Check memory capacity for model metadata, queues and preprocessing, and verify that the server provides enough PCIe connectivity for the planned accelerator and network layout.

AMD’s host analysis includes a specific eight-GPU, two-socket vLLM test with Llama 3.3 70B. Its result is evidence about that topology, model and server configuration—not a general ranking of CPUs for every inference server. Reproduce your own model, accelerator count, batching policy and SLO.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

General-purpose service nodes

Benchmark the API tier, cache, database, retrieval and queue at the same concurrency and durability settings expected in production. Include failover and background work such as compaction, backups and telemetry. In a power- or space-constrained rack, the number of useful servers delivered within the power budget can matter more than the peak score of one socket.

How to interpret published benchmarks

Vendor figures describe particular hardware, software, workloads and methods. They are useful for forming a shortlist, not for converting directly into “agents per CPU.”

Published result Scope and qualification Safe use
2.37× normalized geometric mean for AMD EPYC 9965 AMD’s 2026 modeled two-socket rack comparison against a NVIDIA Vera baseline under a 100 kW rack budget, using infrastructure proxies Evidence about that rack model and suite; not an end-to-end agent rate
1.46× normalized geometric mean for Intel Xeon 6980P The same AMD 2026 modeled comparison and baseline Compare only within the stated model and workloads
3.30× normalized geometric mean for projected AMD “Venice” Projected, not a shipping benchmark result, in the same AMD rack model Roadmap indication, not a procurement measurement
24-way concurrency and 60-minute window Intel’s 2026 deterministic Terminal-Bench replay across Xeon 6, fifth-generation AMD EPYC and Arm v9.2A instances Methodology context; not a recommended production concurrency
174% uplift AMD’s reported geomean uplift for EPYC 9006 CPU-centric agent pipelines versus Xeon 6980P in its named study Vendor-reported result tied to that pipeline and configuration

AMD’s rack analysis explicitly says: “The set doesn’t model full end-to-end agent pipelines; it isolates the infrastructure layers those pipelines depend on.” Intel notes that “real-world agent behavior is inherently dynamic,” which is why deterministic replays still need validation against production traces.

For a neutral, compute-focused reference, SPEC CPU 2026 separates SPECrate throughput from SPECspeed single-task completion time. Its run rules are intended to support fair and objective CPU benchmarking, and public results must follow those rules or be clearly labeled estimates. SPEC CPU stresses processor, memory subsystem and compiler; it does not represent your storage, network, accelerator, sandbox or service-level latency. Pair it with an end-to-end agent test.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.
Independent reader supportYour contribution helps us test, update, and keep practical guides available for everyone.Support on Ko-Fi

Build an end-to-end comparison test

  1. Freeze the software. Record operating-system image, kernel, runtime, framework, model-serving version, drivers, compiler, database schema, indexes and container images.
  2. Match the hardware. Use equivalent memory capacity and channel population, storage devices, network adapters, accelerator count and firmware. Document any unavoidable difference.
  3. Replay the trace. Preserve request mix, tool fan-out, payload sizes, retries, sandbox lifetime and cancellation behavior. Run warm-cache and cold-cache variants when both occur in production.
  4. Sweep concurrency. Test below saturation, at the target operating point and beyond it. Capture throughput, p50/p95/p99 latency, queue depth and error rate at every step.
  5. Separate stages. Attribute time to orchestration, retrieval, tool execution, database, storage, network and accelerator interaction. Stage data prevents a fast CPU from hiding a slow disk or service.
  6. Run a sustained test. Continue long enough to expose thermal and power behavior, garbage collection, cache churn, compaction and background jobs.
  7. Repeat for failure modes. Include sandbox churn, worker restarts, accelerator back-pressure, database failover and network retries if those events matter to your SLO.
  8. Calculate capacity. Report useful workflows per second per server and per rack, the power consumed at that point, and the headroom before the first SLO fails.

Keep the raw trace, configuration and measurement scripts with the result. Without them, a benchmark number cannot be reproduced or audited when software and firmware change.

Best Value
Sale
Anker USB C Hub, 5-in-1 USBC to HDMI Splitter with 4K Display | 85W Max PD, 1 Powered USB-C 5Gbps & 2 Powered USB-A 3.0 5Gbps Data Ports, for MacBook Pro, MacBook Air, Dell and More (Black)
  • 5-in-1 Connectivity: Equipped with a 4K HDMI port, a 5 Gbps USB-C data port, two 5 Gbps USB-A ports, and a USB C 100W PD-IN port. Note: The USB C 100W PD-IN port supports only charging and does not support data transfer devices such as headphones or speakers.
  • Powerful Pass-Through Charging: Supports up to 85W pass-through charging so you can power up your laptop while you use the hub. Note: Pass-through charging requires a charger (not included). Note: To achieve full power for iPad, we recommend using a 45W wall charger.
  • Transfer Files in Seconds: Move files to and from your laptop at speeds of up to 5 Gbps via the USB-C and USB-A data ports. Note: The USB C 5Gbps Data port does not support video output.
  • HD Display: Connect to the HDMI port to stream or mirror content to an external monitor in resolutions of up to 4K@30Hz. Note: The USB-C ports do not support video output.
  • What You Get: Anker 332 USB-C Hub (5-in-1), welcome guide, our worry-free 18-month warranty, and friendly customer service.

Common selection mistakes and fixes

Buying the most cores

Symptom: high theoretical throughput but poor p99 latency or low accelerator utilization. Fix: test per-thread orchestration, memory locality, synchronization and host I/O at target concurrency.

Benchmarking only model inference

Symptom: the model server looks healthy while tools, retrieval or sandboxes queue. Fix: replay the entire workflow and include every co-located service.

Using unlike configurations

Symptom: a CPU is credited for a result obtained with more memory channels, faster storage or a different accelerator. Fix: match the platform or state exactly which component changed.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

Ignoring tail latency

Symptom: average response time meets the target but users see timeouts during bursts. Fix: make p95/p99 limits and queue depth part of the acceptance test.

Trusting a projected or vendor-only figure as a buying verdict

Symptom: procurement is based on a roadmap estimate or a vendor’s preferred workload. Fix: use it to shortlist candidates, then run a controlled test on the intended server.

Under-sizing memory and I/O

Symptom: paging, remote-NUMA traffic, storage wait or network queues dominate CPU time. Fix: size resident data, populate memory channels correctly and validate PCIe, storage and network paths.

Power, cooling and total platform capacity

Record power at the measured operating point, not only the processor’s nominal specification. Include memory, storage, network cards, accelerators, fans and conversion losses. A denser server may deliver more work per rack unit, while a lower-power system may allow more nodes within a fixed rack budget. Compare useful workflows per kilowatt and per rack position using the same SLO and workload.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

Check the facility’s inlet temperature, cooling method, circuit limits and acoustic or service constraints. Firmware power policies can change sustained performance; keep them consistent during testing and document the production policy before ordering.

Procurement checklist

  • Agent framework, language runtimes and container or VM isolation method documented.
  • CPU/GPU split and server role identified for every node pool.
  • Trace includes concurrency, tool mix, retrieval, state, retries and sandbox behavior.
  • Throughput, p95/p99 latency, memory, I/O, accelerator utilization and error targets written down.
  • Candidate systems tested with matched memory, firmware, software and power settings.
  • NUMA, PCIe, network and storage topology reviewed against the deployment diagram.
  • Capacity reported per server and per rack, with power and cooling headroom.
  • Architecture, driver, support and lifecycle compatibility confirmed with the operations team.
  • Vendor benchmark claims labeled with their hardware, workload, date and methodology.
  • A repeatable benchmark package retained for future CPU, runtime and firmware changes.

What information is still needed for an exact SKU

An exact recommendation requires at least the agent framework and software architecture, CPU/GPU division, target concurrency, workload trace, latency and throughput SLOs, memory footprint, server and accelerator compatibility, deployment geography, budget and rack power limit. Product availability, prices, roadmaps and benchmark disclosures can change, so revalidate those details when you are ready to purchase.

Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon at the time of purchase will apply.

Leave a Reply

Your email address will not be published. Required fields are marked *

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

More from the Wire

  1. World desk4 min
    How to Spot an AI Voice Scam Before Sending MoneyDon’t rely on how a caller sounds. Pause, call back through a known number, and verify the emergency with another trusted person before sending money.
  2. Mountain View desk4 min
    Google’s SynthID Detector: How to Check AI-Generated Images, Video and AudioGoogle’s SynthID Detector looks for an embedded watermark in supported images, video and audio. Here is what its results do—and do not—show.
  3. Redmond desk20 min
    How to create a link to File or Folder in Windows 11Windows 11 gives you several ways to point to a file or folder without moving or duplicating it. You can create a desktop shortcut,…
Recommended PC Tool
Recommended PC Tool
PC Slower Than It Used to Be?Free scan - under a minute
Crashes, No Sound, or Screen Glitches?Free driver scan

Two free Windows tools

One Free Minute Could Fix That PC

Before you go - each of these free tools takes about a minute and tackles what quietly slows a Windows PC down.

Special offer. View Outbyte info, uninstall instructions, EULA, and Privacy Policy.