What’s actually slowing this PC down?
Pick the symptom - the matching free tool is one click away.
SSIS error 0x80004005 is a generic failure code, not a diagnosis. The actionable cause is usually in the OLE DB records that follow it: a SQL Server Agent connection problem, an OLE DB provider/editor incompatibility, or data-flow corruption caused by memory pressure. Capture the complete error text, identify where the package runs, and then apply the matching branch below.
What SSIS 0x80004005 means
SQL Server Integration Services (SSIS) commonly reports this HRESULT as DTS_E_OLEDBERROR. The same value can represent very different failures. Microsoft documents examples including “Protocol error in TDS stream,” “Communication link failure,” and “TCP Provider: An existing connection was forcibly closed by the remote host.” Other cases occur while an OLE DB editor lists identifiers, or after a data-flow buffer is written to disk under low-memory conditions.
As an Amazon Associate I earn from qualifying purchases.
Therefore, reinstalling SSIS or changing a random connection string is unlikely to be a reliable first move. The text after 0x80004005, the task that failed, the provider name, and the execution host determine which repair is appropriate.
Capture the complete error chain first
Do not work from a dialog that shows only the hexadecimal code. Save the full execution output from the failing run and record the following details:
#1 Best Overall
- 【Wide Application】This precision screwdriver set has 120 bits, complete with every driver bit you’ll need to tackle any repair or DIY project. In addition, this repair kit has 22 practical accessories, such as magnetizer, magnetic mat, ESD tweezers, suction cup, spudger, cleaning brush, etc. Whether you're a professional or a amateur, this toolkit has what you need to repair all cell phone, computer, laptops, SSD, iPad, game consoles, tablets, glasses, HVAC, sewing machine, etc
- 【Humanized Design】This electronic screwdriver set has been professionally designed to maximize your repair capabilities. The screwdriver features a particle grip and rubberized, ergonomic handle with swivel top, provides a comfort grip and smoothly spinning. Magnetic bit holder transmits magnetism through the screwdriver bit, helping you handle tiny screws. And flexible extension shaft is useful for removing screw in tight spots
- 【Magnetic Design】This professional tool set has 2 magnetic tools, help to save your energy and time. The 5.7*3.3" magnetic project mat can keep all tiny screws and parts organized, prevent from losing and messing up, make your repair work more efficient. Magnetizer demagnetizer tool helps strengthen the magnetism of the screwdriver tips to grab screws, or weaken it to avoid damage to your sensitive electronics
- 【Organize & Portable】All screwdriver bits are stored in rubber bit holder which marked with type and size for fast recognizing. And the repair tools are held in a tear-resistant and shock-proof oxford bag, offering a whole protection and organized storage, no more worry about losing anything. The tool bag with nylon strap is light and handy, easy to carry out, or placed in the home, office, car, drawer and other places
- 【Quality First】The precision bits are made of 60HRC Chromium-vanadium steel which is resist abrasion, oxidation and corrosion, sturdy and durable, ensure long time use. This computer tool kit is covered by our lifetime warranty. If you have any issues with the quality or usage, please don't hesitate to contact us
- The package name, task name, and connection manager named in the error.
- Every OLE DB record, including the provider-specific message after
DTS_E_OLEDBERROR. - The provider and driver name selected by the connection manager.
- The SQL Server and SSIS runtime versions, including whether the deployment is a legacy SQL Server 2005/2008 installation or a current release.
- Whether the package succeeds when started interactively but fails as a SQL Server Agent job.
- Whether the failure occurs during connection testing, metadata editing, or execution of a data-flow task.
Run the package once in the environment where it normally fails, then run the same package interactively if that is safe. A difference between those two runs is often more useful than the HRESULT itself.
Choose the repair branch
| Observed context | Likely branch | First action |
|---|---|---|
| Fails only as a SQL Server Agent job; message mentions TDS, communication, or a connection forcibly closed | SQL Agent connection lifetime | Set the affected connection manager’s RetainSameConnection property to True. |
| Fails while an OLE DB editor enumerates tables or identifiers; provider is associated with a legacy SQL Server 2008 deployment | Provider-property incompatibility | Check for the documented cumulative update that handles missing DBPROP_IDENTIFIERCASE support. |
| Data-flow errors include invalid casts, overflows, duplicate-key violations, or NULL/zero values and success varies with system load | Low-memory buffer pressure | Check for buffer spilling and reduce memory contention. |
| None of the above, or the message names a different provider-specific cause | Provider, schema, credentials, or data issue | Use the detailed OLE DB records to isolate the failing connection and operation before changing settings. |
Fix packages that fail only in SQL Server Agent
A package can work from SSDT, DTExec, or another interactive launch and still fail under SQL Server Agent because the connection is opened and reused differently. Microsoft’s current guidance for the documented Agent failure is to retain the same connection for the affected task.
Set RetainSameConnection in SSMS
- Open SQL Server Management Studio and connect to the instance that owns the job.
- Expand SQL Server Agent, then expand Jobs and open the failing job’s properties.
- Select Steps, choose the step that runs the SSIS package, and click Edit.
- Open the step’s Configuration page and select Connection Managers.
- Select the connection manager associated with the error. Set its
RetainSameConnectionproperty fromFalsetoTrue. - Save the job, run the step again, and inspect the complete history output rather than only the final status.
The property can also be changed directly on the package’s connection manager in the SSIS designer. Make the change on the connection that the failing task actually uses; changing an unused manager will not affect the run.
Free tools Windows power users keep installed
One-click scans. No signup required.
Rank #2
- 【Precision screwdriver set】-- 40Pcs screwdriver set has 30 CRV screwdriver bits which are phillips PH000(+1.2) PH000(+1.5) PH00(+2.0) PH0(+3.0) PH1(+4.0), flathead -0.8 -1.2 -1.5 -2.5 -3.0, torx T1 T2 T3 T4 T5, torx security TR6 TR7 TR8 TR9 TR10 TR15 TR20, triwing Y000(Y0.6) Y00(Y1.5) Y0(Y2.5) Y1(Y3.0), pentalobe P2(0.8) P5(1.2) P6(1.5), MID 2.5, with a screwdriver handle, a double-ended spudger, a long spudger, 3 triangle spudgers, Tweezers, a cleaning brush and a suction cup with SIM card thimble.
- 【Slip-resistant rotatable handle】-- All our screwdriver bits are made of high quality CR-V chrome vanadium steel. CR-V screwdriver bits do not rust easily and are not prone to be broken. The screwdriver handle is made of TPR and PP materials, with a special non-slip design, offering a sense of comfortable. The top of the handle is rotatable design which makes it more convenient to remove the screws; the handle head and the screw head has magnetic adsorption which can quickly replace the screws.
- 【Portable gadgets】-- The triangular spudger is more suitable for opening the screen of the mobile phone.The double-ended spudger is more suitable for opening the back cover of game devices. The long spudger can pry the internal parts of the device.The suction cup can open the screen, which is more convenient to repair the mobile phone.The SIM card thimble can be used to replace the SIM card of the mobile phone. The cleaning brush can clean the dust of the device.Tweezers can grip small parts.
- 【Wide scope of application】-- +1.5/2.0 P2 Y0.6 MID2.5 are used for iPhone7/8/X/XR/11/12/13. +1.2/1.5/2.0/3.0 T2/3/4/5 P2 are used for Samsung/Huawei/Xiaomi and other phones. +1.5/2.0/3.0 T3/4/5/6/9 are used for iPad/Mini/Air/Pro. +1.2/1.5/2.0/3.0/4.0 T2/3/4/5 -2.5 are used for Huawei/Honor and other tablets. P2/5/6 +1.5/2.0/3.0/4.0 T3/4/5/6/7/8/9 Y2.5/3.0 are used for Macbook/Air/Pro. +1.5/2.0/3.0 T5 are for Kindle/Kindle Fire. T6/15 are used Ring Video Doorbell/ Video Doorbell 2/Pro/Elite.
- 【Wide scope of application】-- T8 +1.5/2.0/3.0 are used for PS3/PS4/PS5 controllers and consoles. T6/8/10 are used for Xbox 360/Xbox One/Xbox Series controllers and consoles. Y1.5/2.5/3.0 +1.5/2.0 are used for Switch/NS-Lite/Joy-Con/Wii/Game Boy Advance. T3/8 are used for Fitbit wristband/folding knife. +1.2/1.5/2.0/3.0/4.0 T3/4/5/6/7/8/9 Y2.5/3.0 -2.5 are used for Microsoft/Acer/Dell and other laptops. +1.2/1.5/2.0/3.0/4.0 -0.8/1.2/1.5/2.5/3.0 are used for Desktop Computer/Watch/Glasses/Toy.
Interpret the result
- If the job now succeeds, the failure was related to connection reuse or lifetime in the Agent execution context. Keep the setting only for the connection that needs it and document the reason.
- If the message still reports a TDS protocol error, a communication-link failure, or a remote host closing the TCP connection, continue investigating SQL Server reachability, network interruptions, and the provider-specific record.
RetainSameConnectionaddresses the documented SSIS connection-lifetime scenario; it does not repair a broken network path. - If the package fails in both Agent and interactive execution, move to the provider/editor or memory branches instead of treating Agent as the sole cause.
Handle an OLE DB provider or editor failure
Microsoft notes that “The DTS_E_OLEDBERROR error code has many causes.” One documented SQL Server 2008 case occurs when an OLE DB provider does not implement DBPROP_IDENTIFIERCASE. SSIS can fail while the editor attempts to list identifiers, even though the underlying database is reachable.
Confirm that this is the identifier-property case
- Record the provider name and the exact operation that triggers the error. This branch is most relevant when opening an OLE DB source or destination editor, listing tables, or retrieving metadata.
- Check the installed SQL Server and SSIS runtime version. The documented fix applies to a legacy SQL Server 2008 scenario, not automatically to every current provider.
- Look in the detailed error records for wording about identifier properties, unsupported metadata, or failure while enumerating objects. Do not infer this cause from the hexadecimal code alone.
- Check the cumulative-update level for that SQL Server 2008 installation against Microsoft’s support article for the fix. Apply the applicable update through your normal change-control process.
- Restart the affected design or execution components as required by the update, reopen the package, and repeat the metadata operation.
After the documented servicing change, SSIS ignores failure of the unsupported property and uses a default identifier value. That behavior is a compatibility workaround, not proof that every provider problem is solved. A different provider error, authentication failure, inaccessible object, or malformed query needs its own investigation.
Do not generalize the legacy fix
The DBPROP_IDENTIFIERCASE case is tied to a specific provider/runtime combination. On a newer SQL Server or SSIS deployment, first verify that the same provider and error record are present and that the vendor supports the installed driver. Installing an old cumulative update on an unrelated version is not a safe substitute for identifying the actual provider failure.
Rank #3
- The original electronics toolkit: Designed for computer, smartphone, tablet, and gaming repair, backed by thousands of free instructions.
- Intentional selection: All the tools you need. A 64 precision bit driver set, tweezers, flex extension, opening tools, and anti-static wristband.
- Secure design: Magnetic case and foam insert ensure secure storage and transportation. Additionally, the inside of the lid serves as a sorting/organization tray.
- Lifetime Warranty: We'll replace anything that breaks, as long as you own it.
Diagnose low-memory data-flow failures
Memory pressure can make a data-flow task report misleading secondary errors. Microsoft explains that, after a low-memory notification, the data-flow engine can write buffers to disk temporarily. In affected legacy scenarios, values may be replaced with NULL or zero, producing invalid casts, overflows, duplicate-key violations, or other constraint errors that eventually surface as 0x80004005.
Look for the characteristic pattern
- The same package sometimes succeeds and sometimes fails depending on system load.
- The first visible error is a conversion, overflow, duplicate-key, NULL, or zero-value problem rather than a clear connection refusal.
- The failure appears during a large or parallel data flow and disappears when the workload is smaller.
- A temporary file named
DTS.tmpgrows under the data-flow task’sBufferTempStoragePath.
A growing DTS.tmp file is evidence that buffers are spilling to disk. It does not by itself prove that every bad value came from memory pressure, so correlate the file activity with the failing task and timestamps.
Reduce contention in a controlled order
- Check available physical memory while the package runs, including the SQL Server instance and the machine executing SSIS. Record whether another application is consuming memory at the same time.
- If SSIS and SQL Server share a computer, review SQL Server’s
max server memorysetting. Lowering it can leave room for the SSIS runtime, but make the change only after considering the database workload and your normal capacity controls. - Stop or reschedule memory-heavy applications during the package window.
- Run SSIS on a separate computer from the SQL Server instance when the current host cannot provide predictable memory headroom.
- Change parallel data-flow work to serial execution where practical. Fewer simultaneous buffers reduce peak memory demand, although elapsed time may increase.
- Rerun the package and compare the detailed data errors, memory behavior, and
DTS.tmpactivity.
Adding physical memory is another documented mitigation when the workload genuinely exceeds the host’s capacity. These actions address resource pressure; they do not correct a genuinely bad cast, duplicate key in the source data, or invalid destination constraint. If the same row fails under low-load conditions, inspect the data and metadata separately.
Rank #4
- 【59 in 1 Precision Screwdriver Set】Small screwdriver set contains 44 screwdriver bits, Phillips PH000,PH00,PH0,PH1,PH2; Flathead -1.0, -1.5 -2.0,-3.0; Torx T1 T2 T3 T4 T5, Torx security TR6 TR7 TR8 TR9 TR10 TR15 TR20; Triwing Y0.6, Y1.5. Y2.3, Y3.0; Pentalobe P2(0.8) P5(1.2); Triangle 2.3; U-type U2.6; H-type: H0.9, H1.3, H1.5, H2.0, H2.5, H3.0; MID-type: MID; Sleeve: M2.5, M3.0, M3.5, M4.0, M4.5, Cross 2.0, G3.8, G4.5
- 【Unique Handle Design】Ergonomic design handle, more energy-saving operation, batch head built-in strong magnet, easy to adsorb the batch head. The screwdriver bit is made of high quality CRV steel, which is wear-resistant and hard.
- 【Multi-Functional Accessories】Mini Tool kit contains 15 accessories for a variety of repair needs, including a magnetic plus or minus area to increase or decrease the magnetism of the bit, a long pry bar, a scimitar shaped pry bar, four triangular pry blades, three double-ended pry bars, tweezers, a black cleaning brush, a SIM card thimble, and a suction cup. Note: The package is made of PP material without carton and user manual.
- 【Practical Storage Box】Compartments are categorized for placement, each CRV precision bit is marked with a model number for easy identification, neatly dispensed for easy storage and searching. The box is sturdy and durable with strong clasps that protect each accessory well. The bits are mini (long 28mm, diameter 3.98mm) for precision work, not suitable for large screws.
- 【Wide Scope of Application】Suitable for iPhone/Samsung/Huawei and other cell phones; Mini/Air/Pro and Huawei/Honor and other laptops; Macbook/Air/Pro; Kindle/Kindle Fire; Ring Video Doorbell/ Video Doorbell 2/Pro/Elite; PS4/PS5/XOBX game console controllers and consoles, and PC laptops , watches, glasses, jewelry, toys, flight models, drones, cameras, RC cars, and some small appliances like coffee makers.
Separate a real data error from a memory symptom
Once memory pressure has been reduced, isolate the data-flow component that reports the first invalid value. Use a smaller source range or a staging destination, and record the column, row, and conversion involved. Verify that source and destination data types, lengths, precision, scale, and NULLability agree. A duplicate-key or overflow that remains reproducible with ample memory is a data or schema issue, even if the original run also contained 0x80004005.
Do not “fix” corrupted-looking NULL or zero values by replacing them blindly in a transformation. First establish whether they were present in the source, introduced by a conversion, or produced during buffer pressure. Changing values can hide the underlying failure and create incorrect loads.
When the common branches do not fit
If the complete OLE DB record points to another provider-specific condition, keep the investigation narrow:
Best Value
- 64-in-1 Precision Screwdriver Set: This small screwdriver set includes 48 bits (Phillips, Flathead, Torx, Torx security, Triwing, Pentalobe, Hex, Triangle, U-type, Square, SIM, MID, OVAL, Gamebit, Nut driver). It's a complete electronics repair kit that has been professionally designed to repair computers, PC, laptops, Macbooks, tablet, phones, PS4 PS5, XBOX, Switch, eyeglasses, drone, watches, Ring doorbells and more
- Ergonomic & Magnetic Design: The super smooth swivel cap on the top of the handle makes it easier to rotate screws with less effort. This mini screwdriver features an ergonomic non-slip design and rubberized handle that provides a comfortable grip and precise control. The built-in strong magnet ensures magnetic bit holder transmits magnetism through the screwdriver tip to help you with tiny screws
- Practical Accessories: Our electronics tool kit comes with 8 types of 15 essential accessories. Magnetizer can enhance the magnetism of the screwdriver tip, pointed tweezers make it easy to handle screws and tiny components, spudger and hook tool is effective for connecting/disconnecting components, scraping off adhesives, suction cup, pry tools, opening picks and brush to help open and clean your device
- Organize & Portable Storage: All screwdriver bits are stored in rubber bit holder which marked with type and size for fast recognizing. The rubber bit holder can be fixed on the shelf of the sturdy plastic case, also can be removed for easy access, making it more convenient for you to perform repairs. The case provides secure protection and organized storage, while being lightweight and portable for easy transportation
- Premium Quality & Warranty: STREBITO manufactures premium quality, pro-grade screwdriver set. The precision bits are CNC machined to be precise, made of 60HRC Chromium-vanadium steel which is resist abrasion, oxidation and corrosion. This micro screwdriver set is covered by our lifetime warranty. If you have any issues with the quality or usage, simply contact customer service for troubleshooting help
- Test the named connection manager independently from the data-flow task.
- Confirm that the account used by the execution host has access to the server, database, objects, and required permissions.
- Check that the provider selected by the package is installed in the bitness used by the SSIS runtime. A package launched from a 32-bit designer can behave differently from a 64-bit Agent execution, so record which host actually ran it.
- Compare the package’s configuration and parameter values between interactive and Agent runs. An empty server name, database, or credential can produce a generic OLE DB error.
- Review the first failure in the chain. Later “task failed” messages are often consequences, not causes.
These checks do not replace the provider’s own diagnostic message. If the error names a database object, authentication mechanism, network endpoint, or SQL statement, resolve that named issue before changing SSIS buffer or connection-lifetime settings.
Verify the repair and document it
- Run the smallest safe test that exercises the same connection and task.
- Run the complete package in its normal execution context, including SQL Server Agent if that is where production runs occur.
- Confirm that the detailed OLE DB records no longer contain the original message and that row counts, constraints, and destination values are correct.
- Repeat the run under a representative workload. A one-time success during a quiet period does not prove that low-memory pressure is gone.
- Record the runtime version, provider, changed property, cumulative-update level, memory conditions, and test result so a future deployment can reproduce the working configuration.
Because 0x80004005 is generic, the durable fix is the one that matches the accompanying record and execution conditions. Treat a bare “package failed” status as incomplete evidence and preserve the full chain for the next diagnosis.
Quick Recap
As an optional shortcut after the manual checks, Outbyte PC Repair can address some common Windows system issues and reduce certain configuration and cleanup work; it complements antivirus software, does not replace it, results vary, and no tool repairs every SSIS crash. It supports Windows 11, 10, 8 and 7 with a free trial by category for at least two days, followed by a subscription.
Crashes, No Sound, or Screen Glitches?
Random freezes, missing sound and display glitches usually trace back to one bad driver. Find and replace yours safely.Free scan · under a minuteWindows Errors? Fix Them Before They Spread
Repair common Windows errors and clear accumulated junk for a smoother, more stable PC - no reinstall needed.Free scan · no reinstallProduct prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon at the time of purchase will apply.