Halloween DealsAmazon USHalloween week deals: useful picks before month-endAmazon US: current deals, useful picks and tech finds.Check DealsPC HealthRecommendedCrashes, freezes, slowdowns? Check your PC nowSpot repairable issues before they interrupt work.Check PCHalloween DealsAmazon USOctober picks are moving - compare before checkoutAmazon US: current deals, useful picks and tech finds.See Picks×
FREEDOM251

Freedom251 › Blog › centrifuge selection

How to Choose Compact Laboratory Equipment for a Small Research Space

By Freedom251 Team · · 12 min read

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

Choose compact laboratory equipment by what your protocol must do, then prove that the instrument can be installed, operated and serviced safely in the available room. A small footprint is only one constraint: it does not establish sample compatibility, performance, containment or regulatory suitability.

Before requesting prices, document the method, sample formats, throughput, performance range, hazards, utilities, clearances, delivery route and ownership costs. The University of Vermont Environmental Health and Safety checklist and the World Health Organization procurement guide both treat those checks as prerequisites to a sound purchase.

As an Amazon Associate I earn from qualifying purchases.

Start with the protocol, not the catalogue dimensions

“Compact” describes size, not capability. A small instrument can still need dedicated exhaust, cooling, a high-current circuit, heavy lifting equipment, restricted access or substantial service clearance. Conversely, a physically larger unit may be the only practical choice if it handles the required vessels, force, temperature range or throughput.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

Write a one-page requirement sheet before looking at models. Use the protocol, validated method or standard operating procedure as the source of each requirement. If a requirement is unknown, mark it for resolution rather than assuming that a small benchtop device will cover it.

#1 Best Overall
Elebase USB to USB C Adapter for iPhone 18 Pro Max,USBC Car Charger Adapter | 4Pack Type C Female to A Male Cable Converter for Apple Duo 17 16 15 14 Plus,iWatch Watch 12 11 10,iPad 9 8 Air,Airpods 5 4
  • Read Before You Buy — No Video Output: These adapters support charging and USB 2.0 data transfer, but cannot transmit video signals. Except for standard USB webcams (which use USB data only), they are not compatible with HDMI/DisplayPort cables, video-capable USB-C hubs, or docking stations with video output.
  • Convert USB-A Ports to USB-C: Designed to connect USB-C earphones, cables, flash drives, card readers, and other USB-C accessories to standard USB-A ports. Plug-and-play with no drivers or software required.
  • Aluminum Alloy Housing: Built with a sturdy aluminum alloy shell that aids in heat dissipation and protects against daily wear and scratches. Designed to maintain a stable and secure connection.
  • Compact & Travel-Friendly: The ultra-compact design allows the adapter to stay plugged into your device without blocking adjacent ports or adding bulk, reducing wear and tear on your original USB ports.
  • 12-Month Warranty: Backed by a 12-month manufacturer warranty for peace of mind. Designed to meet strict quality control standards for reliable everyday performance.
Requirement What to record Why it affects selection
Method The procedure, endpoint and acceptance criteria Determines the instrument function and documented performance you need.
Samples and vessels Material, volume, tube or plate format, number of samples and compatibility limits Prevents buying an instrument that cannot physically hold or safely process the samples.
Performance Required range, accuracy, repeatability, force, temperature or environmental control “Compact” cannot substitute for a method requirement.
Throughput Samples per run, runs per day, changeover time and likely growth A low-capacity device may fit the room but create a queue or make future protocols impossible.
Hazards Chemical vapors, biological aerosols, heat, pressure, radiation or other controlled hazards Hazards determine containment, exhaust, placement, training and approval requirements.
Environment Permitted temperature, humidity, vibration, dust and noise conditions Some instruments require a controlled environment or isolation from vibration and heat.
Workflow Loading, unloading, cleaning, data transfer and shared-use arrangements Operating clearances and access can matter more than the listed footprint.

Separate essential specifications from preferences

Classify each requirement as mandatory, preferred or optional. Mandatory items include a validated operating range, vessel compatibility, safety controls and utilities that the room can actually provide. Preferences such as a smaller display, network connection or extra automation should be considered only after those gates are met.

Allow for plausible protocol growth. The procurement guidance from CASRAI recommends matching centrifuge force and capacity to current and plausible future protocols; the same principle applies to other equipment. Buying the smallest possible unit can create a second procurement when sample numbers or formats change.

Measure the room as an installation, not just a bench

Record the instrument’s installed footprint from the manufacturer’s installation drawing, then add every clearance the manual specifies. The University of Vermont guidance calls for checking actual room and equipment clearances, delivery and access, weight, ventilation and maintenance access before purchase.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

Measure the complete operating envelope

  • Measure width, depth and height with lids, doors, drawers, cables and hoses in their operating positions.
  • Reserve the manufacturer’s service clearance on every required side. A unit that fits tightly against a wall may be impossible to repair or clean.
  • Check aisle width, egress, nearby doors, emergency equipment and the space needed to load samples without blocking a walkway.
  • Confirm bench or floor loading limits and the route for moving the equipment. Include packaging, pallet dimensions, elevator limits, ramps, stairs and turning radii.
  • Check door swing, lid travel and access to removable rotors, vessels, filters, reservoirs or waste containers.
  • Account for heat released into the room. A compact device can still increase room cooling demand.

Verify the delivery route before placing an order

Ask the supplier for packed dimensions, shipping weight, unpacked weight and any lifting or anchoring instructions. Compare those figures with doorways, elevators, corridors and the final bench. The room may accept the instrument while the building cannot accept the crate. Facilities should approve unusual rigging, floor loading or anchoring before funds are committed.

Resolve environmental and exhaust questions

The Vermont checklist specifically asks whether equipment will produce chemical vapors, biological aerosols or heat and whether it needs additional exhaust or cooling. Treat those as facility design questions, not assumptions based on a small enclosure. Determine whether the room needs local exhaust, a biological safety cabinet, a dedicated cooling solution, vibration isolation or restricted placement. Institutional Environmental Health and Safety (EHS) and facilities staff should make that determination with the manufacturer.

Rank #2
Anker USB-C Hub, 5-in-1 USB Hub for Laptops, 4K HDMI Multiport Adapter | USB C Dongle with 90W Max Power Delivery, 3×5Gbps USB A Data Ports, for MacBook, Dell, and More (Charger Not Included)
  • 5-in-1 USB-C Hub: Experience comprehensive connectivity featuring a Power Delivery input, two USB-A 2.0 ports, a USB-A 3.0 port, and an HDMI port. (Note: The USB-C power delivery input port is only for connecting an external wall charger to power your laptop and cannot power peripheral devices.)
  • 90W Pass-Through Charging: Achieve optimal charging with 90W pass-through power to your laptop, supported by a total input of 100W, with the hub reserving 10W for operational efficiency. (Note: Wall charger not included.)
  • Quick Data Transfers: Accelerate your productivity with rapid data transfers using a high-speed 5Gbps USB 3.0 port and two 480Mbps USB 2.0 ports.
  • 4K HDMI Display: Enhance your visual experience with a hub capable of delivering 4K resolution at 30Hz in both mirror and extend modes. Please note that this hub is compatible with MacBook (macOS 12 and newer), Windows 10 and 11, ChromeOS, and laptops equipped with DP Alt Mode and Power Delivery. Note: This device is not compatible with Linux.
  • What You Get: Anker USB-C Hub (5-in-1, 4K HDMI), welcome guide, 18-month warranty, and our friendly customer service.

Confirm utilities and shutdown requirements

Use the current installation specification rather than a marketplace listing. Have facilities verify the circuit and all connections at the proposed location.

Utility or service Checks to document Typical failure if ignored
Electrical power Voltage, frequency, amperage, plug type, circuit rating, dedicated-circuit requirement and emergency-power expectations Nuisance trips, unsafe adapters, inability to start or loss of samples during an outage.
Water and drains Supply quality, pressure, connection size, backflow protection, drain location and spill control Leaking connections, contamination risk or a device that cannot complete its cycle.
Gases and compressed air Gas identity, purity, pressure, regulators, cylinders or house supply and shutoff access Incorrect process conditions, incompatible fittings or an unapproved cylinder installation.
Exhaust and ventilation Required airflow, duct route, discharge location, make-up air and heat removal Vapor or aerosol accumulation, overheating or an installation that fails EHS review.
Network and data Network port, cybersecurity rules, local storage, export format and whether connectivity is optional Lost records or an instrument that cannot join the institution’s network.
Emergency power and shutdown What must remain powered, what must stop immediately and where shutoff controls are located Unsafe restart, sample loss or inability to isolate a fault.

Ask the supplier to state each requirement in writing. A quotation should identify included plugs, hoses, regulators, stands, software, filters, rotors and other accessories; “not included” items can change the installation cost and schedule.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

Make safety and compliance a purchase gate

Compact equipment is not automatically low risk. EHS and facilities should review the intended use, room, hazards and controls before procurement. The University of Houston centrifuge guidance states that equipment must be operated by trained personnel only. Apply that standard to any device with moving parts, heat, pressure, chemicals, biological material or stored energy.

Questions for EHS and the manufacturer

  • What hazards can the method generate during normal operation, loading, unloading, cleaning and failure?
  • Is containment required for the sample, aerosol, vapor, spill or waste stream?
  • Are guarding, lid locks, interlocks, imbalance detection, over-temperature protection or emergency stops required?
  • Which certifications, inspections, local regulations or institutional approvals apply?
  • What personal protective equipment, decontamination method and waste route are specified?
  • What training must be completed, and how will competency be documented?
  • What maintenance, inspection and calibration records must be retained?

Do not infer suitability for hazardous work from a sealed lid or small enclosure. For biohazardous or chemically hazardous applications, ask EHS and the manufacturer to identify the appropriate containment, exhaust and decontamination configuration. If they cannot document it, stop the purchase until the gap is resolved.

Compare instruments with a documented decision matrix

Once an option passes the method and facility gates, compare alternatives on the same written criteria. The WHO publication Selection of basic laboratory equipment for laboratories with limited resources (2000) describes specification sheets, quotation assessment, supplier evaluation, receipt, maintenance, energy needs and second-hand purchases. It is a foundational framework; current local requirements and current manufacturer documents still control the decision.

Rank #3
Sale
Anker USB C Hub, 7in1 Multi-Port USB Adapter, 4K@60Hz USBC to HDMI Splitter | 85W Max PD, 2 USB 3.0 & 1 USBC Data Ports, SD/TF Card Reader, for Laptops/Mac and Other Type C Devices (Charger Not Included)
  • Sleek 7-in-1 USB-C Hub: Features an HDMI port, two USB-A 3.0 ports, and a USB-C data port, each providing 5Gbps transfer speeds. It also includes a USB-C PD input port for charging up to 100W and dual SD and TF card slots, all in a compact design.
  • Flawless 4K@60Hz Video with HDMI: Delivers exceptional clarity and smoothness with its 4K@60Hz HDMI port, making it ideal for high-definition presentations and entertainment. (Note: Only the HDMI port supports video projection; the USB-C port is for data transfer only.)
  • Double Up on Efficiency: The two USB-A 3.0 ports and a USB-C port support a fast 5Gbps data rate, significantly boosting your transfer speeds and improving productivity.
  • Fast and Reliable 85W Charging: Offers high-capacity, speedy charging for laptops up to 85W, so you spend less time tethered to an outlet and more time being productive.
  • What You Get: Anker USB-C Hub (7-in-1), welcome guide, 18-month warranty, and our friendly customer service.
Comparison axis Evidence to request Decision question
Method fit Operating range, accuracy or performance claims, compatibility list and validation or application documentation Can it perform the intended method under our stated conditions?
Capacity and workflow Samples per run, supported formats, cycle time, changeover and expansion options Will it meet present throughput without blocking the workflow?
Space and installation Installed dimensions, service clearances, weight, bench or floor requirements and delivery data Can the room receive, operate and service it safely?
Utilities and environment Electrical, water, gas, exhaust, cooling, heat load, network and emergency-power specifications Can facilities provide and isolate every required service?
Safety and compliance Interlocks, guarding, containment, certifications, training and inspection requirements Will EHS approve the intended use and location?
Ownership Price, accessories, consumables, warranty, service response, spare parts, calibration, energy and disposal Is the total cost and support burden acceptable?

Use a quotation package, not a product page

Request the specification sheet, installation requirements, operating manual, safety documentation, warranty, service and maintenance terms, consumables list and an itemized quotation. Ask the supplier to identify model, configuration, included accessories and delivery assumptions. Record the document revision or date because specifications, certifications, stock and service coverage can change.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

Score only after non-negotiable gates pass

  1. Reject any option that fails a mandatory method, sample, safety or utility requirement.
  2. For the remaining options, score capacity, footprint, workflow, service and ownership against the same weights.
  3. Document assumptions, such as an optional rotor, dedicated circuit or annual calibration.
  4. Have the protocol owner, EHS, facilities and procurement review the same comparison sheet.
  5. Keep the rejected options and reasons in the procurement record so a later change in protocol can be evaluated quickly.

Budget for the full ownership cycle

The purchase price is only one line. The WHO framework explicitly includes supplier assessment, equipment receipt, maintenance, energy needs and second-hand equipment. Build a total-ownership worksheet before selecting the lowest quotation.

Cost or obligation What to include
Initial equipment Base unit, required modules, stands, rotors, adapters, software and installation.
Consumables Tubes, plates, filters, seals, reagents, liners and other per-run or replacement items.
Utilities Electrical work, plumbing, gas, exhaust, cooling, network and emergency-power changes.
Service Preventive maintenance, calibration where required, inspection, travel, response time and labor.
Training Initial operator training, refresher training, competency records and method-specific instruction.
Downtime and continuity Loaner or backup arrangements, sample recovery, duplicate accessories and business-continuity planning.
End of life Decontamination, data removal, disposal, transport and any regulated waste handling.

Ask who stocks replacement parts, where service technicians are located, how long common parts remain available and what happens after the warranty. A low-cost instrument with no local service, unavailable consumables or long downtime may cost more operationally than a better-supported alternative.

When a mini or microcentrifuge is the right compact choice

A mini or microcentrifuge is a conditional example, not a universal answer for a small laboratory. It makes sense only when the protocol calls for centrifugation and the unit supports the required sample formats, capacity, relative centrifugal force, temperature control and safety features.

NuAire describes centrifuges ranging from mini units that hold a few small tubes to high-capacity units and ultracentrifuges; refrigeration and network connection are among possible features. That range shows why the word “mini” cannot stand in for a specification.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.
Rank #4
Sale
UGREEN USB to USB C Adapter Combo 4-Pack, 10Gbps USB C Converter Space Gray | Data transfer & Fast charging for MacBook, iPhone 17/16/15, iPad, Samsung Galaxy, Apple Watch
  • Dual Converters, Infinite Potential:Includes 2× USB C male to USB A female adapters and 2× USB A male to USB C female adapters. Perfect for a wide range of uses—tablets with Bluetooth keyboards, expand USB ports on macbook, and more. Two different converters for all your daily needs
  • Next-Level 10Gbps & 3A Charging: No more slow 480Mbps, this usb to usb c adapter has a transfer speed of up to 10Gbps, allowing you to do more transferring in less time. This usb adapter fits both USB A and USB C charger, supporting up to 3A fast charging
  • Upgraded Exquisite Craftsmanship: With an aluminum alloy housing and metal connector, the usbc to usb adapter is extremely durable and sturdy. Rigorously tested to withstand more than 10,000 times of plugging and unplugging, ensuring long-lasting performance
  • Broad Compatible: The usb c to usb adapter widely supports all USB C/ USB A devices like laptops, tablets, cellphones, car chargers, and phone chargers. Such as compatible with MacBook Pro/Air 2023/2022, Thunderbolt 4/3 Devices,Apple MagSafe Watch 9/8/7/SE/Ultra, iPad Pro 2022/2021, Samsung Galaxy S23/S20/S10, and iPhone 17/16/15 Pro. Plug and play
  • Please Note: To reach 10Gbps speed, keep the cable under 3.3 ft. For USB A Male to USB C adapters, try flipping the USB C connector. USB C Male to USB A adapters support bidirectional 10Gbps transfer within 3.3 ft

Centrifuge comparison checklist

Attribute What to verify before purchase
Rotor and tube compatibility Rotor type, adapters, tube material, volume, sealing and whether the supplied configuration matches the protocol.
Capacity Number of samples per run, balancing requirements and capacity for likely future protocols.
Speed and force Maximum and controllable speed or relative centrifugal force, with the method’s required range documented.
Temperature Whether refrigeration is required, the controlled range, heat load and recovery behavior specified by the manufacturer.
Footprint and access Installed dimensions, lid or door swing, service clearance, bench loading and delivery route.
Utilities Voltage, current, circuit, ventilation, heat rejection and any network connection or emergency-power need.
Safety Lid interlock, imbalance detection, guarding, emergency stop, documented electrical and mechanical safety and containment options.
Maintenance Cleaning, inspection, rotor life, replacement parts, maintenance intervals, records and service availability.

CASRAI procurement guidance specifically calls for checking force and capacity, footprint, circuit rating, door swing, ventilation, documented electrical and mechanical safety, imbalance detection, lid interlocks, biohazard containment and maintenance documentation. Treat each item as a yes-or-no procurement question, not as a marketing feature.

Safe centrifuge operation is part of the specification

  1. Confirm that the operator has completed the required training. Houston’s guidance states that centrifuges must be operated by trained personnel only.
  2. Inspect the rotor, buckets, adapters, tubes and lid before each run; remove damaged or incompatible parts.
  3. Balance every load according to the manufacturer’s instructions, including mass, position and opposing tubes.
  4. Close and secure the lid before starting. Never open or defeat the interlock while the rotor is moving.
  5. Stop the run and follow the incident procedure for unusual vibration, noise, imbalance, leakage or an error condition.
  6. Clean and decontaminate according to the approved procedure, then record maintenance and inspections in the equipment log.

For hazardous material, consult EHS and the manufacturer about sealed rotors, buckets, containment, decontamination and exhaust. A compact centrifuge is not automatically suitable for every biological or chemical hazard.

Independent reader supportYour contribution helps us test, update, and keep practical guides available for everyone.Support on Ko-Fi

A six-step procurement workflow

  1. Write the protocol requirements. Record method, sample and vessel formats, throughput, performance range, temperature or environmental controls and future needs.
  2. Identify hazards with EHS. Decide whether containment, exhaust, cooling, restricted placement, special training or additional approvals are required.
  3. Survey the installation site. Measure footprint and service clearance; verify weight, bench or floor loading, delivery route, doors, egress, heat and vibration conditions.
  4. Confirm utilities and documents. Obtain the current specification sheet, installation requirements, operating manual, safety documentation, warranty, service terms and consumables list. Have facilities confirm power, water, gas, exhaust, network and emergency-power requirements.
  5. Compare total ownership. Use an itemized quotation and decision matrix covering accessories, consumables, maintenance, calibration, training, parts, energy, downtime and disposal.
  6. Approve, receive and commission. Obtain protocol-owner, EHS, facilities and procurement approval; schedule delivery and installation; perform acceptance checks; train operators; start maintenance and inspection records.

Common small-space purchasing mistakes

Choosing by outer dimensions alone

Why it fails: The unit may need more service clearance, ventilation, lid travel or weight support than the bench provides.
Fix: Compare the installed drawing and delivery route, then have facilities sign off on the measured location.

Assuming a universal compact instrument exists

Why it fails: Discipline, protocol, sample type, hazard class, throughput and budget differ. No single equipment list or model ranking is justified without those facts.
Fix: Specify the method first and reject any option that cannot document compatibility.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

Ignoring optional accessories

Why it fails: A base unit may not include the rotor, adapters, stand, software, filters or containment hardware needed for the method.
Fix: Require an itemized quotation and list every accessory as included, optional or not available.

Best Value
Anker USB C Hub, 5-in-1 USBC to HDMI Splitter with 4K Display | 85W Max PD, 1 Powered USB-C 5Gbps & 2 Powered USB-A 3.0 5Gbps Data Ports, for MacBook Pro, MacBook Air, Dell and More (Black)
  • 5-in-1 Connectivity: Equipped with a 4K HDMI port, a 5 Gbps USB-C data port, two 5 Gbps USB-A ports, and a USB C 100W PD-IN port. Note: The USB C 100W PD-IN port supports only charging and does not support data transfer devices such as headphones or speakers.
  • Powerful Pass-Through Charging: Supports up to 85W pass-through charging so you can power up your laptop while you use the hub. Note: Pass-through charging requires a charger (not included). Note: To achieve full power for iPad, we recommend using a 45W wall charger.
  • Transfer Files in Seconds: Move files to and from your laptop at speeds of up to 5 Gbps via the USB-C and USB-A data ports. Note: The USB C 5Gbps Data port does not support video output.
  • HD Display: Connect to the HDMI port to stream or mirror content to an external monitor in resolutions of up to 4K@30Hz. Note: The USB-C ports do not support video output.
  • What You Get: Anker 332 USB-C Hub (5-in-1), welcome guide, our worry-free 18-month warranty, and friendly customer service.

Leaving utilities until installation day

Why it fails: A dedicated circuit, drain, gas line, exhaust or cooling modification can delay the project or make the room unsuitable.
Fix: Obtain written utility requirements and facilities approval before issuing a purchase order.

Treating training and maintenance as paperwork

Why it fails: Incorrect loading, skipped inspections or undocumented cleaning can create safety incidents, unreliable results and warranty disputes.
Fix: Budget training, assign equipment ownership, keep a maintenance log and define inspection and calibration intervals.

Assuming a small device is automatically suitable for hazardous work

Why it fails: Containment, decontamination and exhaust depend on the material and procedure, not the enclosure size.
Fix: Obtain written EHS and manufacturer confirmation for the exact hazard and configuration.

Free tools Windows power users keep installed

One-click scans. No signup required.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

Acceptance checks before the first experiment

Receiving the crate is not the same as accepting the equipment. Use a commissioning checklist tied to the quotation and protocol.

  • Verify model, configuration, serial number and included accessories against the purchase order.
  • Inspect for shipping damage and record photographs or exceptions before signing delivery documents.
  • Confirm placement, leveling, anchoring, clearances, ventilation and utility connections.
  • Run the manufacturer’s installation and startup checks; record software or firmware versions where applicable.
  • Test required operating ranges with the approved acceptance method, not merely an empty power-on test.
  • Verify safety functions such as interlocks, alarms, imbalance detection or emergency shutdown where applicable.
  • Confirm operator training, written instructions, cleaning supplies, waste route and maintenance log.
  • Store manuals, certificates, service contacts, warranty terms and acceptance results where users can find them.

Questions to send with every quotation request

  • What are the exact operating and installed dimensions, including all required clearances?
  • What are packed and unpacked weights, delivery requirements and lifting instructions?
  • Which voltage, frequency, amperage, plug, circuit, water, gas, exhaust, cooling and network services are required?
  • Which accessories, rotors, adapters, software, stands, filters and containment components are included?
  • What sample materials, vessel formats, volumes, temperatures and performance ranges are documented?
  • What safety features and certifications are provided, and what hazards are excluded?
  • What training, preventive maintenance, calibration, inspection and decontamination are required?
  • What are warranty limits, service response, parts availability and expected consumable lead times?
  • What installation, acceptance testing and operator documentation are included in the quotation?

Final decision rule

Buy the smallest instrument that demonstrably meets the protocol, safety, utility, access, service and growth requirements—not merely the smallest box. If any mandatory answer is missing, pause the order, obtain the manufacturer’s documentation and have EHS, facilities and procurement resolve it. That discipline protects the room, the operators, the samples and the budget.

Product prices and availability are accurate as of the date/time indicated and are subject to change. Any price and availability information displayed on Amazon at the time of purchase will apply.

centrifuge selectionequipment procurementlab safetylaboratory equipmentsmall research space

Leave a Reply

Your email address will not be published. Required fields are marked *

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

Recommended PC Tool
Recommended PC Tool
Outdated Drivers Are Slowing You DownFree scan - exact matches
PC Slower Than It Used to Be?Free scan - under a minute

Two free Windows tools

One Free Minute Could Fix That PC

Before you go - each of these free tools takes about a minute and tackles what quietly slows a Windows PC down.

Special offer. View Outbyte info, uninstall instructions, EULA, and Privacy Policy.