On a legacy Windows system that boots with NTLDR and uses Boot.ini, add /NoSerialMice:COMx to the operating-system boot entry, replacing COMx with the UPS’s actual port—for example, /NoSerialMice:COM1. Back up Boot.ini first, then restart. This stops Windows from probing that port for a serial mouse; it does not disable the port or install UPS support.

Compatibility: This is a legacy Windows NT/2000-era fix, not a normal Windows 10 or 11 setting. Microsoft says the built-in Windows UPS service does not support COM-port UPS units in Windows Vista and later; use a supported USB or network connection where possible (Microsoft’s UPS minidriver documentation).

Why Windows mistakes a UPS for a mouse

Some older UPS units communicate over RS-232 serial. During startup, legacy Windows versions can probe COM ports for serial pointing devices. A device that continuously sends data may be misidentified as a serial mouse, and mouse support can interfere with UPS software trying to use that port. Microsoft documented this behavior for Windows 2000 and earlier NT-family systems (Microsoft Knowledge Base archive).

Free tools Windows power users keep installed

One-click scans. No signup required.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

The boot option controls serial-mouse detection only. It does not turn off the physical COM port, change the UPS protocol, provide a driver, or guarantee that the UPS software supports your model.

#1 Best Overall
USB to RJ50 10P10C Cable - Control for APC Control Cable 6.5 FT
  • Establish Critical UPS Communication:Utilize this dedicated USB to RJ50 Control Cable to enable reliable data exchange and monitoring between your for APC Smart-UPS device and a connected computer,server,or workstation
  • Precise RJ50 10P10C Connector:Features the correct USB to RJ50 10P10C Cable termination specifically designed for APC UPS management ports,ensuring a perfect and secure fit (Note: This is NOT a 8P8C RJ45/Ethernet cable)
  • Broad for APC UPS Compatibility:This essential USB to RJ50 Control Cable works seamlessly with numerous for APC UPS series including Smart-UPS,Smart-UPS XL,Smart-UPS VT,Back-UPS,Back-UPS Pro,and Matrix-UPS models requiring the specified interface
  • Effortless Plug-and-Play Setup:Achieve instant connectivity with driver-free operation.Simply connect the USB to RJ50 10P10C Cable between your UPS and computer's USB port for immediate communication without software installation hassles
  • Durable 6FT Replacement Solution:Provides a robust and cost-effective USB to RJ50 Control Cable replacement (1.8 meters long) for original APC cords like AP9827,940-0127B,940-0127C,and 940-0127E,maintaining signal integrity

Check that this procedure fits your computer

  • Windows NT, Windows 2000, or another legacy installation using Boot.ini: The switch may apply. Confirm that the computer actually uses the older NTLDR boot configuration.
  • Windows Vista or later: Do not expect this legacy switch or the built-in Windows UPS service to enable a serial UPS. Use a supported USB connection, compatible vendor software, or network management instead.
  • UPS connected by USB: Serial-mouse detection is generally not the issue. Check the USB connection, driver, and management software.

Find the correct COM port

Use the port selected in the UPS software and cross-check it against the computer’s hardware listing, Device Manager where available, physical port label, expansion-card configuration, or UPS documentation. A native connector labeled COM1 is not necessarily the port used by a USB-to-serial adapter: Windows may assign an adapter COM3, COM4, or another number.

The number in the switch must match the port Windows probes. If the UPS is on COM2, use /NoSerialMice:COM2, not COM1. A wrong number can leave the problem in place or suppress mouse detection on an unrelated port.

Back up and edit Boot.ini

  1. Back up C:Boot.ini to a safe location before changing it. A syntax error can affect boot selection.
  2. If needed, make hidden and system files visible in Explorer. If Windows prevents editing, temporarily remove the file’s read-only, hidden, and system attributes; restore the original attributes afterward.
  3. Open Boot.ini in a plain-text editor and find the operating-system entry you actually use.
  4. Add a space and the targeted switch to the end of that entry’s existing options. Do not replace the line or alter its multi(), disk(), rdisk(), or partition() values.
  5. Save the file, restore its original attributes if you changed them, and restart.
  6. After startup, test whether the UPS software can open the port and report UPS status.

For example, a Windows 2000 entry might look like this; the path, label, and existing options vary by installation:

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.
Rank #2
Feanteek APC Serial Cable USB to RS232 DB9 UPS Communication Cable 940-0024 Smart Signalling Serial Cable for APC UPS SUA-1000ICH SUA-1500ICH APC SUA2200RM and SURT Models(APC Part# 940-0024(1.8M))
  • 【Application Scenes】Work well with all APC UPS product lines - Back-UPS, Back-UPS Pro, Smart-UPS, Smart-UPS v/s, Matrix-UPS and Symmetra Power Array.
  • 【Great Qulity】USB to RS232 DB9 940-0024 UPS communication cable smart signaling for APC UPS,for APC UPS SU SUA SUM and SURT Models
  • 【Adapter Cable】Compatible replacement for APC UPS part 940-0024C and 940-0024E.Durable molded cable on both ends. Tested to perform as the original APC parts 940-0024C and 940-0024E
  • 【Drivers】Build in FT232RL chip,ensures stable transmission of signals, Automatic installation and update support. Compatible with all windows version Win7/8/10/11/Vista/XP, and Mac OS/Linux/Android.
  • 【Sweet Tips】Alias:apc part number 940-0024,apc 940-0024 cable replacement,console cable apc,console cable. apc cable, apc cable usb, apc data cable, apc ups cable, apc serial cable, apc ups usb cable, apc ups communications cable, apc ups connect, apc ups console cable, console cable for apc ups, apc usb data cable
[operating systems]
multi(0)disk(0)rdisk(0)partition(1)WINNT="Microsoft Windows 2000 Professional" /fastdetect /NoSerialMice:COM1

Microsoft’s archived instructions describe adding the option to the relevant boot entry, restoring file attributes, and restarting (archived Microsoft KB article).

Choose a targeted or global setting

For a UPS, the targeted form is usually the safer choice:

/NoSerialMice:COM1

It stops serial-mouse detection on COM1 while leaving detection on other COM ports available. The documented forms include:

Rank #3
FT231XS USB RS232 to DB9 Communication Cable for APC UPS 940 0024C Serial Kable
  • FT231XS usb to db9 serial cable for APC UPS 940 0024C
  • FT231XS USB to DB9 Serial Programming Cable for APC UPS 940 0024E
  • FT231XS Chip, Full support Windows, Android, Mac, Linux, Vista etc
  • Package : 1pc FT231XS usb to DB9 MALE serial programming cable
  • /NoSerialMice:COM1 — exclude COM1.
  • /NoSerialMice:COM1,2,3 — exclude COM1, COM2, and COM3.
  • /NoSerialMice — disable serial-mouse detection on all COM ports.

Use the global form only when no serial mouse or other pointing device depends on Windows detecting one. It can break a real serial mouse on another port.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

Multi-boot systems and existing options

Each operating-system line in Boot.ini is a separate boot entry. Add the switch to the entry used for UPS communication; changing an unused entry has no effect on the current installation. If multiple legacy Windows installations use the UPS, update each applicable entry.

Older APC PowerChute installations could add the switch automatically. Inspect the existing entry before editing: if the option is already present with the wrong port, correct it rather than adding a second, potentially conflicting version.

Rank #4
TRIPP LITE USB to Serial Adapter Cable, USB-A to DB9 RS232, Male-to-Male, 5 Feet / 1.5 Meters, 3-Year Warranty (U209-000-R)
  • USB-A TP RS-232 SERIAL ADAPTER CABLE: Connect devices with a 9-pin DB9 RS-232 serial port, such as modems, digital cameras, PDAs and ISDN terminals, to the USB Type-A port on your computer or laptop from up to 5 feet / 1.5 meters away.
  • SERIAL ADAPTER: Supports data transfer rates up to 230 kbps. Premium double-shielded cable with tinned copper braid and aluminum Mylar foil shield that eliminates cross-talk and reduces EMI/RFI interference.
  • EASY TO USE: Adapter does not require external power. Drivers are easily available to download on Tripp Lite's website.
  • BROAD COMPATIBILITY: Compatible with most Windows, Mac and Linux computers, and Android Tablets / Phones. Compatible with Windows 2000 up to 11, Mac OS X 10.6 through 10.12, Linux Redhat 7.3, 8.0 and 9.0 (Linux Kernel 2.4.31 and above already includes built-in drivers), Android Tablets with USB Host Mode (OTG) support and Android OS version 3.2 and above with addtional USB Host Mode (OTG) cable (such as Tripp Lite's U052-06N).
  • RELIABLE PRODUCT FULLY BACKED AND SUPPORTED: This product is covered by a 3-Year Limited Warranty and is supported by Tripp Lite's Chicago-based expert technical support team over phone and email.

If the UPS still is not detected

  1. Verify the cable first. A connector that fits is not proof that the cable has the right wiring or signaling. APC warns that Smart-UPS serial cables can be proprietary and that an incorrect cable can cause serious problems, including unexpected UPS output behavior. Match the cable to the exact UPS model and software (APC cable guidance).
  2. Recheck the COM number. Confirm the port in the UPS software and Windows. USB-to-serial adapters can receive a different or changing COM assignment.
  3. Check the adapter driver. Some adapters require a vendor-specific driver. APC documents one setup using a 940-0272A cable in which installing the Prolific PL2303 driver and restarting resolves discovery problems; this applies to that documented configuration, not every adapter (APC adapter guidance).
  4. Release the port from competing software. Close terminal or diagnostic tools and stop competing UPS utilities, modem services, or other software that may already have opened the COM port. A mouse-detection switch cannot make a port available if another program owns it.
  5. Check model and signaling compatibility. Legacy UPS software may expect a particular simple or smart signaling mode. On older Windows versions, smart-signaling units can require a model-specific UPS minidriver. Confirm compatibility among the UPS, cable, software, adapter, and operating system.
  6. Confirm the Windows generation. The built-in Windows UPS service’s serial support is a legacy feature. Windows Vista and later do not support COM-connected UPS units through that service; a third-party utility does not automatically make every serial UPS or adapter compatible.

APC’s current software guide describes model-dependent USB, serial, and network management options, including PowerChute Serial Shutdown and PowerChute Network Shutdown. Check the supported-products information for your exact UPS before choosing software (APC UPS management software guide).

Independent reader supportYour contribution helps us test, update, and keep practical guides available for everyone.Support on Ko-Fi

Advanced Windows 2000 case

If a device is still being identified as a mouse despite the boot option, Microsoft documented a separate Windows 2000 workaround involving the SkipEnumerations registry value under the affected device’s hardware-enumeration key (Microsoft Knowledge Base archive). Treat this as a version-specific, advanced measure—not the first-line UPS fix. The registry path depends on the enumerator, device ID, and instance ID, so a generic copy-and-paste registry command is unsafe. Back up the registry and identify the exact device key before considering changes.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

Modern options for a serial-only UPS

  • Use native USB if your UPS model supports it, together with management software that lists the model as compatible.
  • Use network management for supported UPS models with a network management card, especially when several servers need coordinated shutdown.
  • Use a documented adapter and cable if serial is unavoidable. Verify support for the UPS model, operating system, software, and signaling mode rather than relying on connector shape alone.
  • Keep a dedicated legacy host when an irreplaceable UPS supports only older serial software. This can be more practical than trying to add unsupported serial UPS support to a current Windows PC.

If editing Boot.ini prevents startup

Boot into a recovery or installation environment appropriate for that Windows version and restore the backup. If the rest of the entry is valid, remove only the newly added /NoSerialMice... option. Restart and test the UPS cable, COM assignment, drivers, and software separately.

Best Value
DB9 to 10 Pin RJ50 or 8 Pin RJ45 RS232 Serial Cable for SMX/SMT/SMC Series UPS APC Smart-UPS 5G/4.5G (6ft)
  • Designed for UPS communication and configuration, compatible with SMX / SMT / SMC series and APC Smart-UPS 5G / 4.5G systems. Supports connection via 10-pin RJ50 or 8-pin RJ45 interface.
  • Provides stable DB9 to RS232 serial data transmission between UPS and computer, ensuring accurate monitoring, management, and system configuration.
  • Compatible with : APC part# 940-0625A, AP940-0625A, AP940-1525A - Smart-UPS 5G(Serial) SMX750, SMX1000, SMX1500, SMX3000 - Smart-UPS 4.5G(Serial) SMT750, SMT1000, SMT1500, SMT2200, SMT3000 - Smart-UPS SURTD - Smart-UPS SMC SMC750, SMC1000, SMC1500, SMC2000, SMC3000
  • length:6ft

Frequently Asked Questions

Does this work on Windows 10 or Windows 11?

It is a legacy Boot.ini option for systems using the older NT loader, not a normal Windows 10 or 11 setting. For a modern PC, use a supported USB or network UPS connection and compatible vendor software.

Will this disable my real serial mouse?

The targeted form disables serial-mouse detection only on the named port. The bare /NoSerialMice form disables it on all COM ports and may stop Windows detecting a serial mouse elsewhere.

Does /NoSerialMice:COM1 disable COM1?

No. It prevents serial-mouse detection on COM1; it does not turn off the port. UPS software can still use it if the cable, driver, software, and port assignment are compatible.

Special offer. See more information about Outbyte and uninstall instructions. Please review EULA and Privacy policy.

Do I need to edit every Boot.ini entry?

No. Edit the entry used by the operating system that communicates with the UPS. Update other entries only if those installations also need the setting.

Can I use any DB9 cable with an APC UPS?

No. APC warns that Smart-UPS serial cables may use proprietary wiring and signaling. Use a cable specified for the exact UPS model and intended software.

What if a USB-to-serial adapter appears as COM4?

Configure the UPS software for the adapter’s actual assigned port and confirm which port Windows probes. Do not assume it is COM1 because the computer has a physical COM1 connector.